National Rejectors, Inc. GmbH, Buxtehude OPERATION<br />
Allocate a coin signal line to a coin channel<br />
With the help of <strong>WinEMP</strong> you can specify which coin channel is to pass<br />
via which coin signal line of the connecting cable from the coin validator to<br />
the vending machine (for the function of this allocation please refer to the<br />
appropriate instructions for the coin validator).<br />
To select the coin signal line please proceed as described below starting<br />
at the table screen (see page 13):<br />
• on the table screen under the heading Coin outputs 1-6 tick the<br />
required coin signal line (output) with the mouse by clicking the box in<br />
the line of the respective coin channel and if necessary<br />
• remove the tick under another output by clicking the box.<br />
When leaving this screen, you will be asked whether the data entered<br />
is to be saved in the device. By clicking on the button YES the new<br />
values would be saved in the coin validator.<br />
Assign the coin impulse number to a coin channel<br />
(only G-18.mft)<br />
Every coin inserted into the coin validator passes on an impulse to the<br />
vending machine control via the appropriate coin signal line. An impulse<br />
tells the vending machine control that a coin has been inserted. On<br />
principle, 1–4 impulses per coin can be assigned to the coin channel<br />
allocated to a coin (see label of the coin validator). However, it only makes<br />
sense to assign more than 1 if the vending machine control does not have<br />
sufficient coin signal lines and in the case of the introduction of new coins<br />
(e.g. Euro coins) the greater value of these coins has to be simulated for<br />
the vending machine control by a number of coin impulses, i.e. when e.g. a<br />
2 £ coin is inserted, four coin impulses would be passed onto the vending<br />
machine control via the coin signal line allocated to the 50 p coin. The<br />
factory setting for each coin channel is 1 impulse.<br />
If you wish to allocate a different impulse number to a coin channel, you<br />
must call up a pull down menu with the possible coin impulse number 1–4<br />
and select the required number by calling up the table screen (see<br />
page 13) and then clicking the mouse in the right column under the<br />
heading Pulses in the row of the respective channel using the arrow<br />
button or the white input field.<br />
When leaving this screen, you will be asked whether the data entered<br />
is to be saved in the device. By clicking on the button YES the new<br />
values would be saved in the coin validator.<br />