CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Send wake-up signal via return signal line (not for ECV totalizer) 90 WinEMP – G-13.mft If the coin validator is supposed to send a wake-up signal to the machine via the return signal line, as soon as it is woken up by insertion of a coin: The G-13.mft can then neither send a return signal to the machine when the return lever/button is operated nor use the return signal line to sort coins. 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word WAKE-UP FUNCTION. 3 On the righthand side, click TRANSMIT WAKE-UP SIGNAL (tick). If you click again the tick would be removed and no wake-up signal would be sent to the machine. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude

WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Configure another totalizer operation WinEMP enables you to configure another operating mode within the G-13.mft totalizer model: 1 In the main menu, select menu item SETTINGS and then DEVICE VARIANT. A pop-up window opens. 2 Select the required totalizer mode (mark). 3 Confirm your selection with OK. The window closes. 4 Adapt all the function settings to suit the selected operating mode (see other sections in this subchapter and separate G-13.mft instructions for the totalizer about settings using the switching blocks). 5 Click BACK to store the setting in the G-13.mft. National Rejectors, Inc. GmbH, Buxtehude 91

<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER)<br />

Configure another totalizer operation<br />

<strong>WinEMP</strong> enables you to configure another operating mode within the<br />

G-13.mft totalizer model:<br />

1 In the main menu, select menu item SETTINGS and then DEVICE<br />

VARIANT.<br />

A pop-up window opens.<br />

2 Select the required totalizer mode (mark).<br />

3 Confirm your selection with OK.<br />

The window closes.<br />

4 Adapt all the function settings to suit the selected<br />

operating mode (see other sections in this subchapter<br />

and separate G-13.mft instructions for the<br />

totalizer about settings using the switching blocks).<br />

5 Click BACK to store the setting in the G-13.mft.<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

91