CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Define sorting time 84 WinEMP – G-13.mft Now that you have just defined via which sorting control line the respective coin type will be sorted, the sorting time now has to be set as the switching time for the external sorting device: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word SORTING. 3 On the righthand side, enter the desired SORTING TIME using the keyboard. The sorting time can be 300 to 1000 ms and is converted into 4-ms increments. A time of 500 ms should be set for the NRI sorting device. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude

WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Enable return signal line for sorting If you have selected the return signal line for external sorting, it must be enabled for sorting. National Rejectors, Inc. GmbH, Buxtehude The G-13.mft can then neither send a return signal to the machine when the return lever/button is operated nor a wakeup signal. 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word SORTING. 3 On the righthand side under RELEASE Click on (tick) the box. By clicking on the box again the tick would be deleted and the return signal line cannot be selected for external sorting. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. 85

<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER)<br />

Enable return signal line for sorting<br />

If you have selected the return signal line for external sorting, it must be<br />

enabled for sorting.<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

The G-13.mft can then neither send a return signal to the<br />

machine when the return lever/button is operated nor a wakeup<br />

signal.<br />

1 Select menu item EXTRA and then OPTIONS.<br />

The dialog box BASIC SETTINGS AND OPTIONS opens.<br />

2 In the "table of<br />

contents" on<br />

the left-hand<br />

side, select the<br />

index word<br />

SORTING.<br />

3 On the righthand<br />

side<br />

under RELEASE<br />

Click on (tick)<br />

the box.<br />

By clicking on<br />

the box again<br />

the tick would<br />

be deleted and the return signal line cannot be selected for external<br />

sorting.<br />

4 Confirm your entry with OK and close the window again or proceed<br />

to the next setting in this dialog box first and confirm all your settings<br />

later.<br />

5 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />

85