WinEMP - NRI
WinEMP - NRI WinEMP - NRI
CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Select display 72 WinEMP – G-13.mft If the totalizer is connected to a vending machine/tester with display, you must specify the number of digits to be displayed (4 or 5-digit display): 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word TOTALIZER INTERFACE. 3 On the righthand side select the required DISPLAY. 4 For a 5-digit timer or TV totalizer display, activate (tick) HOUR/MINUTE, if e.g. "90" is to be displayed as "1h30" (HOUR) or "1-30" (MINUTE) (depending on the switch position S2.10). Clicking again would remove the tick and activate the standard display format. 5 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 6 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude
WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER) Activate inventory function (only timer/TV totalizer) If the timer or TV totalizer is to be transmit inventory pulses for each coin inserted for an external counter: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word TOTALIZER INTERFACE. 3 On the righthand side activate (tick) INVENTORY PULSES. Clicking again would remove the tick and no inventory pulses would be transmitted. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude 73
- Page 21 and 22: WinEMP - G-13.mft National Rejector
- Page 23 and 24: WinEMP - G-13.mft General operating
- Page 25 and 26: WinEMP - G-13.mft GENERAL PROGRAM S
- Page 27 and 28: WinEMP - G-13.mft National Rejector
- Page 29 and 30: WinEMP - G-13.mft Perform tests Nat
- Page 31 and 32: WinEMP - G-13.mft Select memory blo
- Page 33 and 34: WinEMP - G-13.mft National Rejector
- Page 35 and 36: WinEMP - G-13.mft 8 Configuration N
- Page 37 and 38: WinEMP - G-13.mft G-13.mft with MDB
- Page 39 and 40: WinEMP - G-13.mft National Rejector
- Page 41 and 42: WinEMP - G-13.mft National Rejector
- Page 43 and 44: WinEMP - G-13.mft Teach coin types/
- Page 45 and 46: WinEMP - G-13.mft National Rejector
- Page 47 and 48: WinEMP - G-13.mft CONFIGURATION - F
- Page 49 and 50: WinEMP - G-13.mft CONFIGURATION - F
- Page 51 and 52: WinEMP - G-13.mft CONFIGURATION - F
- Page 53 and 54: WinEMP - G-13.mft CONFIGURATION - F
- Page 55 and 56: WinEMP - G-13.mft CONFIGURATION - F
- Page 57 and 58: WinEMP - G-13.mft CONFIGURATION - F
- Page 59 and 60: WinEMP - G-13.mft CONFIGURATION - F
- Page 61 and 62: WinEMP - G-13.mft CONFIGURATION - F
- Page 63 and 64: WinEMP - G-13.mft CONFIGURATION - F
- Page 65 and 66: WinEMP - G-13.mft CONFIGURATION - F
- Page 67 and 68: WinEMP - G-13.mft CONFIGURATION - F
- Page 69 and 70: WinEMP - G-13.mft CONFIGURATION - F
- Page 71: WinEMP - G-13.mft CONFIGURATION - F
- Page 75 and 76: WinEMP - G-13.mft CONFIGURATION - F
- Page 77 and 78: WinEMP - G-13.mft CONFIGURATION - F
- Page 79 and 80: WinEMP - G-13.mft CONFIGURATION - F
- Page 81 and 82: WinEMP - G-13.mft CONFIGURATION - F
- Page 83 and 84: WinEMP - G-13.mft CONFIGURATION - F
- Page 85 and 86: WinEMP - G-13.mft CONFIGURATION - F
- Page 87 and 88: WinEMP - G-13.mft CONFIGURATION - F
- Page 89 and 90: WinEMP - G-13.mft CONFIGURATION - F
- Page 91 and 92: WinEMP - G-13.mft CONFIGURATION - F
- Page 93 and 94: WinEMP - G-13.mft CONFIGURATION - F
- Page 95 and 96: WinEMP - G-13.mft CONFIGURATION - F
- Page 97 and 98: WinEMP - G-13.mft CONFIGURATION - F
- Page 99 and 100: WinEMP - G-13.mft CONFIGURATION - F
- Page 101 and 102: WinEMP - G-13.mft CONFIGURATION - F
- Page 103 and 104: WinEMP - G-13.mft CONFIGURATION - F
- Page 105 and 106: WinEMP - G-13.mft CONFIGURATION - F
- Page 107 and 108: WinEMP - G-13.mft CONFIGURATION - F
- Page 109 and 110: WinEMP - G-13.mft CONFIGURATION - F
- Page 111 and 112: WinEMP - G-13.mft CONFIGURATION - F
- Page 113 and 114: WinEMP - G-13.mft CONFIGURATION - F
- Page 115 and 116: WinEMP - G-13.mft Copy and paste or
- Page 117 and 118: WinEMP - G-13.mft Change token/coin
- Page 119 and 120: WinEMP - G-13.mft National Rejector
- Page 121 and 122: WinEMP - G-13.mft National Rejector
CONFIGURATION – FOR PARALLEL INTERFACE (TOTALIZER)<br />
Select display<br />
72<br />
<strong>WinEMP</strong> – G-13.mft<br />
If the totalizer is connected to a vending machine/tester with display, you<br />
must specify the number of digits to be displayed (4 or 5-digit display):<br />
1 Select menu item EXTRA and then OPTIONS.<br />
The dialog box BASIC SETTINGS AND OPTIONS opens.<br />
2 In the "table of<br />
contents" on<br />
the left-hand<br />
side, select<br />
the index word<br />
TOTALIZER<br />
INTERFACE.<br />
3 On the righthand<br />
side<br />
select the<br />
required<br />
DISPLAY.<br />
4 For a 5-digit<br />
timer or TV<br />
totalizer display, activate (tick) HOUR/MINUTE, if e.g. "90" is to be<br />
displayed as "1h30" (HOUR) or "1-30" (MINUTE) (depending on the<br />
switch position S2.10).<br />
Clicking again would remove the tick and activate the standard<br />
display format.<br />
5 Confirm your entry with OK and close the window again or proceed<br />
to the next setting in this dialog box first and confirm all your settings<br />
later.<br />
6 Click BACK to store the setting in the G-13.mft or proceed to the next<br />
setting on this screen and store all your settings later.<br />
National Rejectors, Inc. GmbH, Buxtehude