CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />

Configure sorting<br />

56<br />

<strong>WinEMP</strong> – G-13.mft<br />

If an external sorting device is connected to the coin validator, the following<br />

settings must be performed in <strong>WinEMP</strong>:<br />

• which sorting control line is to be used to actuate a sorting chute for<br />

the purpose of sorting a specific coin and<br />

• in which period of time is the sorting process to be carried out.<br />

Assign sorting control line to a coin type<br />

If an external sorting device is connected to the coin validator, you can assign<br />

the coin types to be sorted one of three sorting control lines or the return<br />

signal line.<br />

1 In the line of the respective coin channel under the heading<br />

"SORT R 3 2 1" tick the desired sorting control line 1–3 or return signal<br />

line R by clicking on the box and, if necessary,<br />

2 remove the tick set under any other line by clicking the box.<br />

To ensure that the return signal line can be selected for external<br />

sorting it has to be enabled (see section "Enable return signal line<br />

for sorting" in this chapter).<br />

The G-13.mft can then neither send a return signal to the<br />

machine when the return lever/button is operated nor send a<br />

wake-up signal or coin acceptance signal (Casino operation)<br />

to the machine.<br />

3 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />