CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Assign external individual inhibit signal line to a coin type 54 WinEMP – G-13.mft As an alternative to inhibiting coin types/groups using the DIL switches or using the coin validator software, up to six different coin types can be inhibited from the vending machine via the external individual inhibit signal lines. To ensure that the coin validator knows which coin type is to be inhibited via which one of the six signal lines, a signal line must be assigned to the coin type to be inhibited: 1 In the line of the respective coin channel under the heading INHIBIT 6–1 tick the desired line by clicking the box and, if necessary, 2 remove the tick set under any other line by clicking the box. For inhibiting in groups assign all the relevant coin types (e.g. of a currency) to the same line. 3 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude

WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Deactivate/activate teach mode The G-13.mft is usually delivered so that you can teach new tokens or coin types on site on the vending machine in the last eight coin channels (teach channels). You can either fully deactivate this teach function or make it possible for fewer coin channels to prevent, if necessary, any teach channels assigned to important coin types from being overwritten unintentionally. If you want to change teach mode settings: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. In the "table of contents" on the left-hand side, the index word TEACH MODE has already been selected. To deactivate the function: 2a On the righthand side, click TEACH MODE (remove tick). Clicking again would set the tick again and activate the teach mode. To limit the function to specific teach channels: 2b On the right-hand side under ACTIVATE TEACH CHANNELS click (tick) the box of the channel number(s) that is (are) to be enabled on site for the teaching process. Clicking again would delete the tick and inhibit the channel for the teach mode. 3 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 4 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude 55

<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />

Deactivate/activate teach mode<br />

The G-13.mft is usually delivered so that you can teach new tokens or coin<br />

types on site on the vending machine in the last eight coin channels (teach<br />

channels). You can either fully deactivate this teach function or make it<br />

possible for fewer coin channels to prevent, if necessary, any teach<br />

channels assigned to important coin types from being overwritten<br />

unintentionally.<br />

If you want to change teach mode settings:<br />

1 Select menu item EXTRA and then OPTIONS.<br />

The dialog box BASIC SETTINGS AND OPTIONS opens. In the "table of<br />

contents" on the left-hand side, the index word TEACH MODE has already<br />

been selected.<br />

To deactivate the function:<br />

2a On the righthand<br />

side,<br />

click TEACH<br />

MODE (remove<br />

tick).<br />

Clicking again<br />

would set the<br />

tick again and<br />

activate the<br />

teach mode.<br />

To limit the function to specific teach channels:<br />

2b On the right-hand side under ACTIVATE TEACH CHANNELS click (tick) the<br />

box of the channel number(s) that is (are) to be enabled on site for<br />

the teaching process.<br />

Clicking again would delete the tick and inhibit the channel for the<br />

teach mode.<br />

3 Confirm your entry with OK and close the window again or proceed<br />

to the next setting in this dialog box first and confirm all your settings<br />

later.<br />

4 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />