WinEMP - NRI
WinEMP - NRI WinEMP - NRI
CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Assign external individual inhibit signal line to a coin type 54 WinEMP – G-13.mft As an alternative to inhibiting coin types/groups using the DIL switches or using the coin validator software, up to six different coin types can be inhibited from the vending machine via the external individual inhibit signal lines. To ensure that the coin validator knows which coin type is to be inhibited via which one of the six signal lines, a signal line must be assigned to the coin type to be inhibited: 1 In the line of the respective coin channel under the heading INHIBIT 6–1 tick the desired line by clicking the box and, if necessary, 2 remove the tick set under any other line by clicking the box. For inhibiting in groups assign all the relevant coin types (e.g. of a currency) to the same line. 3 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude
WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Deactivate/activate teach mode The G-13.mft is usually delivered so that you can teach new tokens or coin types on site on the vending machine in the last eight coin channels (teach channels). You can either fully deactivate this teach function or make it possible for fewer coin channels to prevent, if necessary, any teach channels assigned to important coin types from being overwritten unintentionally. If you want to change teach mode settings: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. In the "table of contents" on the left-hand side, the index word TEACH MODE has already been selected. To deactivate the function: 2a On the righthand side, click TEACH MODE (remove tick). Clicking again would set the tick again and activate the teach mode. To limit the function to specific teach channels: 2b On the right-hand side under ACTIVATE TEACH CHANNELS click (tick) the box of the channel number(s) that is (are) to be enabled on site for the teaching process. Clicking again would delete the tick and inhibit the channel for the teach mode. 3 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 4 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude 55
- Page 4 and 5: TABLE OF CONTENTS 4 WinEMP - G-13.m
- Page 6 and 7: TABLE OF CONTENTS 6 WinEMP - G-13.m
- Page 9 and 10: WinEMP - G-13.mft GENERAL INFORMATI
- Page 11 and 12: WinEMP - G-13.mft GENERAL INFORMATI
- Page 13 and 14: WinEMP - G-13.mft GENERAL INFORMATI
- Page 15 and 16: WinEMP - G-13.mft 3 Installation In
- Page 17 and 18: WinEMP - G-13.mft INSTALLATION 7 Pl
- Page 19 and 20: WinEMP - G-13.mft Start WinEMP Nati
- Page 21 and 22: WinEMP - G-13.mft National Rejector
- Page 23 and 24: WinEMP - G-13.mft General operating
- Page 25 and 26: WinEMP - G-13.mft GENERAL PROGRAM S
- Page 27 and 28: WinEMP - G-13.mft National Rejector
- Page 29 and 30: WinEMP - G-13.mft Perform tests Nat
- Page 31 and 32: WinEMP - G-13.mft Select memory blo
- Page 33 and 34: WinEMP - G-13.mft National Rejector
- Page 35 and 36: WinEMP - G-13.mft 8 Configuration N
- Page 37 and 38: WinEMP - G-13.mft G-13.mft with MDB
- Page 39 and 40: WinEMP - G-13.mft National Rejector
- Page 41 and 42: WinEMP - G-13.mft National Rejector
- Page 43 and 44: WinEMP - G-13.mft Teach coin types/
- Page 45 and 46: WinEMP - G-13.mft National Rejector
- Page 47 and 48: WinEMP - G-13.mft CONFIGURATION - F
- Page 49 and 50: WinEMP - G-13.mft CONFIGURATION - F
- Page 51 and 52: WinEMP - G-13.mft CONFIGURATION - F
- Page 53: WinEMP - G-13.mft CONFIGURATION - F
- Page 57 and 58: WinEMP - G-13.mft CONFIGURATION - F
- Page 59 and 60: WinEMP - G-13.mft CONFIGURATION - F
- Page 61 and 62: WinEMP - G-13.mft CONFIGURATION - F
- Page 63 and 64: WinEMP - G-13.mft CONFIGURATION - F
- Page 65 and 66: WinEMP - G-13.mft CONFIGURATION - F
- Page 67 and 68: WinEMP - G-13.mft CONFIGURATION - F
- Page 69 and 70: WinEMP - G-13.mft CONFIGURATION - F
- Page 71 and 72: WinEMP - G-13.mft CONFIGURATION - F
- Page 73 and 74: WinEMP - G-13.mft CONFIGURATION - F
- Page 75 and 76: WinEMP - G-13.mft CONFIGURATION - F
- Page 77 and 78: WinEMP - G-13.mft CONFIGURATION - F
- Page 79 and 80: WinEMP - G-13.mft CONFIGURATION - F
- Page 81 and 82: WinEMP - G-13.mft CONFIGURATION - F
- Page 83 and 84: WinEMP - G-13.mft CONFIGURATION - F
- Page 85 and 86: WinEMP - G-13.mft CONFIGURATION - F
- Page 87 and 88: WinEMP - G-13.mft CONFIGURATION - F
- Page 89 and 90: WinEMP - G-13.mft CONFIGURATION - F
- Page 91 and 92: WinEMP - G-13.mft CONFIGURATION - F
- Page 93 and 94: WinEMP - G-13.mft CONFIGURATION - F
- Page 95 and 96: WinEMP - G-13.mft CONFIGURATION - F
- Page 97 and 98: WinEMP - G-13.mft CONFIGURATION - F
- Page 99 and 100: WinEMP - G-13.mft CONFIGURATION - F
- Page 101 and 102: WinEMP - G-13.mft CONFIGURATION - F
- Page 103 and 104: WinEMP - G-13.mft CONFIGURATION - F
<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />
Deactivate/activate teach mode<br />
The G-13.mft is usually delivered so that you can teach new tokens or coin<br />
types on site on the vending machine in the last eight coin channels (teach<br />
channels). You can either fully deactivate this teach function or make it<br />
possible for fewer coin channels to prevent, if necessary, any teach<br />
channels assigned to important coin types from being overwritten<br />
unintentionally.<br />
If you want to change teach mode settings:<br />
1 Select menu item EXTRA and then OPTIONS.<br />
The dialog box BASIC SETTINGS AND OPTIONS opens. In the "table of<br />
contents" on the left-hand side, the index word TEACH MODE has already<br />
been selected.<br />
To deactivate the function:<br />
2a On the righthand<br />
side,<br />
click TEACH<br />
MODE (remove<br />
tick).<br />
Clicking again<br />
would set the<br />
tick again and<br />
activate the<br />
teach mode.<br />
To limit the function to specific teach channels:<br />
2b On the right-hand side under ACTIVATE TEACH CHANNELS click (tick) the<br />
box of the channel number(s) that is (are) to be enabled on site for<br />
the teaching process.<br />
Clicking again would delete the tick and inhibit the channel for the<br />
teach mode.<br />
3 Confirm your entry with OK and close the window again or proceed<br />
to the next setting in this dialog box first and confirm all your settings<br />
later.<br />
4 Click BACK to store the setting in the G-13.mft or proceed to the next<br />
setting on this screen and store all your settings later.<br />
National Rejectors, Inc. GmbH, Buxtehude<br />