<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />

Define coin impulse length<br />

By specifying a certain coin impulse length, with which the coin impulses are<br />

transferred to the vending machine, the coin validator can be adjusted to the<br />

specific processing time of the respective vending machine.<br />

Define how long you want a coin impulse to be present for the vending<br />

machine control system:<br />

1 Select menu item EXTRA and then BASIC SETTINGS.<br />

The dialog box<br />

BASIC SETTINGS<br />

AND OPTIONS<br />

opens. In the<br />

"table of<br />

contents" on<br />

the left-hand<br />

side, the index<br />

word COIN<br />

IMPULSE LENGTH<br />

has already<br />

been selected.<br />

2 On the righthand<br />

side,<br />

enter the desired COIN IMPULSE LENGTH using the keyboard.<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

The coin impulse length can be 5 to 500 ms.<br />

3 Confirm your entry with OK and close the window again or proceed<br />

to the next setting in this dialog box first and confirm all your settings<br />

later.<br />

4 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />