<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />
Assign coin impulse number to a coin type<br />
Every coin accepted by the coin validator passes on at least one impulse to<br />
the vending machine control system via the appropriate coin signal line. An<br />
impulse tells the vending machine control system that a coin has been<br />
accepted. For the vending machine control system to be able to distinguish<br />
between the individual coin values when there are not enough signal lines,<br />
a different number of coin impulses can be assigned to the coin types.<br />
Theoretically, you can assign 1–255 impulses per coin to the coin channel<br />
assigned to one coin.<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
But: Configure the impulse number as low as possible so that coins<br />
can be accepted more quickly.<br />
If there are sufficient coin signal lines, assign an impulse and a<br />
different coin signal line or combination of signal lines to each coin<br />
type (see next section).<br />
If too many coin types have been programmed for the existing coin<br />
signal lines, assign, for example, two impulses and the same coin<br />
signal line to a 1-euro coin as for the 50-cent coin, which is<br />
transmitted with one impulse.<br />
If you want to assign a different impulse number to a coin type:<br />
1 Use the mouse to mark the number currently displayed in the input<br />
field of the respective coin channel under the heading IMP. and<br />
2 enter the desired number using the keyboard.<br />
3 Click BACK to store the setting in the G-13.mft or proceed to the next<br />
setting on this screen and store all your settings later.<br />
47