CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Configure G-13.mft for parallel validator operation Store changes in coin validator and return to main menu 46 WinEMP – G-13.mft This section describes all setting options for the standard and Casino model of the G-13.mft with parallel interface. The next subchapter describes how to configure the G-13.mft totalizer. In this section you find how to perform settings for: • coin signals, • acceptance gate, • accepted coin sensors, • coin inhibit, • teach mode, • coin sorting, • coin rejection, and • wake-up sensor (optional) Configure channelsuperordinate data: coin impulse length, attraction time of acceptance gate, accepted coin sensors, teach mode, Copy, insert, and sorting, delete channel data; coin rejection, name coin wake-up function Simulation for inhibiting via DIL switches Assign sorting control line Assign DIL switch (inhibit) only for single block data-management Assign coin impulse number Assign coin signal line Configure channel-specific data Assign external inhibit signal line National Rejectors, Inc. GmbH, Buxtehude Deactivate using coin validator software

WinEMP – G-13.mft CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR) Assign coin impulse number to a coin type Every coin accepted by the coin validator passes on at least one impulse to the vending machine control system via the appropriate coin signal line. An impulse tells the vending machine control system that a coin has been accepted. For the vending machine control system to be able to distinguish between the individual coin values when there are not enough signal lines, a different number of coin impulses can be assigned to the coin types. Theoretically, you can assign 1–255 impulses per coin to the coin channel assigned to one coin. National Rejectors, Inc. GmbH, Buxtehude But: Configure the impulse number as low as possible so that coins can be accepted more quickly. If there are sufficient coin signal lines, assign an impulse and a different coin signal line or combination of signal lines to each coin type (see next section). If too many coin types have been programmed for the existing coin signal lines, assign, for example, two impulses and the same coin signal line to a 1-euro coin as for the 50-cent coin, which is transmitted with one impulse. If you want to assign a different impulse number to a coin type: 1 Use the mouse to mark the number currently displayed in the input field of the respective coin channel under the heading IMP. and 2 enter the desired number using the keyboard. 3 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. 47

CONFIGURATION – FOR PARALLEL INTERFACE (VALIDATOR)<br />

Configure G-13.mft for parallel validator operation<br />

Store changes in coin<br />

validator and return to<br />

main menu<br />

46<br />

<strong>WinEMP</strong> – G-13.mft<br />

This section describes all setting options for the standard and Casino model<br />

of the G-13.mft with parallel interface.<br />

The next subchapter describes how to configure the G-13.mft<br />

totalizer.<br />

In this section you find how to perform settings for:<br />

• coin signals,<br />

• acceptance gate,<br />

• accepted coin sensors,<br />

• coin inhibit,<br />

• teach mode,<br />

• coin sorting,<br />

• coin rejection, and<br />

• wake-up sensor (optional)<br />

Configure channelsuperordinate<br />

data:<br />

coin impulse length,<br />

attraction time of acceptance gate,<br />

accepted coin sensors,<br />

teach mode,<br />

Copy, insert, and<br />

sorting,<br />

delete channel data;<br />

coin rejection,<br />

name coin<br />

wake-up function<br />

Simulation for inhibiting via<br />

DIL switches<br />

Assign sorting<br />

control line<br />

Assign DIL switch<br />

(inhibit)<br />

only for single block<br />

data-management<br />

Assign coin<br />

impulse number<br />

Assign coin signal<br />

line<br />

Configure channel-specific data<br />

Assign external<br />

inhibit signal line<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

Deactivate using<br />

coin validator<br />

software