WinEMP - NRI
WinEMP - NRI
WinEMP - NRI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>WinEMP</strong> – G-13.mft<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
CONFIGURATION<br />
7 Save entries with OK.<br />
The box closes and the new acceptance band as well as the coin<br />
name is saved in the PC for the channel selected.<br />
Those coins which could not be configured using the data base<br />
must now be taught by inserting the coins.<br />
(8) Insert 30 genuine coins of the<br />
new coin type into the G-13.mft<br />
(representative selection).<br />
For the purpose of verification,<br />
the screen display indicates the<br />
insertion of a coin and starts<br />
counting from 0 to 30. After the 30 th coin has been inserted, the pop-up<br />
window closes.<br />
Please do not change the width of the acceptance band and<br />
leave the sliding bar on 100%.<br />
<strong>WinEMP</strong> has stored the measured values of the inserted coins and<br />
assigned the new acceptance band with 100% to the coin channel. The<br />
percentage value is displayed on the ACCEPTED button.<br />
9 Adapt other settings to suit the new coin type (see section "Configure<br />
G-13.mft for parallel standard/Casino/totalizer, MDB/S1 or cctalk<br />
operation" in this chapter).<br />
10 Save acceptance band and all other settings in the G-13.mft by<br />
clicking BACK.<br />
11 Check acceptance of the newly configured coin (see section "Which<br />
coin type is accepted in which coin channel?" in Chap. 7 "Measured<br />
coin values and channel values").<br />
45