<strong>WinEMP</strong> – G-13.mft<br />

Perform tests<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

PREPARATION<br />

Two basic requirements for the functionality of the G-13.mft are reliable<br />

signal lines between the machine (tester) and the G-13.mft as well as a<br />

perfectly functioning acceptance gate. <strong>WinEMP</strong> enables you to test these<br />

equipment parts.<br />

Test signal lines (only for parallel interface)<br />

Signal lines can only be checked, if the coin validator is supplied<br />

with power by the <strong>NRI</strong> testers G-19.0594/G-19.0651 or G-19.0645/<br />

G-19.0650.<br />

To test the external inhibit signal lines between the vending machine (tester)<br />

and the G-13.mft in validator operation or the reset and common inhibit<br />

signal line between the vending machine (tester) and the G-13.mft in<br />

totalizer operation, select menu item TESTS in the main menu and then<br />

LINE TEST.<br />

While the status display is displaying the message LINES ARE BEING CHECKED<br />

– PLEASE WAIT, the function of the external signal lines is checked automatically.<br />

On the tester, the LEDs assigned to the signal lines light up briefly.<br />

If an LED does not light up, either the connection between the G-13.mft and<br />

the vending machine (tester) is defective (cable, plug-in connections) or a<br />

coin validator component is defective. In this case, please contact the<br />

service technician.<br />

Test acceptance gate<br />

To test the acceptance gate of the G-13.mft, please select menu item<br />

TESTS in the main menu and then GATE TEST.<br />

While the status display is displaying the message GATES ARE BEING CHECKED<br />

– PLEASE WAIT, the function of the acceptance gate is checked automatically.<br />

You can hear the solenoid being activated and released again.<br />

If you can’t hear a noise, the module must be checked.<br />