<strong>WinEMP</strong> – G-13.mft<br />
INSTALLATION<br />
7 Please make sure that the DIL switches of the coin validator are in<br />
the desired positions (see separate instructions for the validator).<br />
8 Insert the chip card in the direction of the arrow into the slot labelled<br />
"Chip Card" on the card reader.<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
If you only want general coin validator data to be displayed using<br />
<strong>WinEMP</strong>, the chip card does not have to be inserted in the card<br />
reader. However, the chip card must be inserted in order to configure<br />
any data.<br />
Connect device environment with tester G-19.0594 (G-19.0651)/<br />
G-19.0645 (G-19.0650)/G-19.0567 and <strong>WinEMP</strong> PC interface G-55.0359 or<br />
adapter pack G-19.0640<br />
If, in addition to the configuration of the coin validator and to the general<br />
diagnostics, the signal lines of the parallel machine interface are also to be<br />
checked, the following device environment must be connected:<br />
Fig. 1b: Connection plan for G-13.mft with parallel interface for testing the signal lines between<br />
machine and validator/totalizer<br />
Fig. 1c: Connection plan for G-13.mft with parallel interface (by means of <strong>NRI</strong> adapter pack<br />
G-19.0640) for testing the signal lines between machine and validator/totalizer<br />
The AMU model, SGI model, and ECV totalizer model as well as<br />
validators/totalizers with wake-up sensor cannot be checked by<br />
means of these testers.<br />