03.03.2013 Views

WinEMP - NRI

WinEMP - NRI

WinEMP - NRI

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>WinEMP</strong> – G-13.mft<br />

INSTALLATION<br />

7 Please make sure that the DIL switches of the coin validator are in<br />

the desired positions (see separate instructions for the validator).<br />

8 Insert the chip card in the direction of the arrow into the slot labelled<br />

"Chip Card" on the card reader.<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

If you only want general coin validator data to be displayed using<br />

<strong>WinEMP</strong>, the chip card does not have to be inserted in the card<br />

reader. However, the chip card must be inserted in order to configure<br />

any data.<br />

Connect device environment with tester G-19.0594 (G-19.0651)/<br />

G-19.0645 (G-19.0650)/G-19.0567 and <strong>WinEMP</strong> PC interface G-55.0359 or<br />

adapter pack G-19.0640<br />

If, in addition to the configuration of the coin validator and to the general<br />

diagnostics, the signal lines of the parallel machine interface are also to be<br />

checked, the following device environment must be connected:<br />

Fig. 1b: Connection plan for G-13.mft with parallel interface for testing the signal lines between<br />

machine and validator/totalizer<br />

Fig. 1c: Connection plan for G-13.mft with parallel interface (by means of <strong>NRI</strong> adapter pack<br />

G-19.0640) for testing the signal lines between machine and validator/totalizer<br />

The AMU model, SGI model, and ECV totalizer model as well as<br />

validators/totalizers with wake-up sensor cannot be checked by<br />

means of these testers.<br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!