<strong>WinEMP</strong> – G-13.mft<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

GLOSSARY<br />

Smallest coin value The smallest coin value for the MDB/S1 and totalizer model<br />

of the G-13.mft is the reference value for data-managing the<br />

→ coin values (and prices). The values of all the coin types<br />

accepted by the G-13.mft must be integral multiples of the<br />

smallest coin value.<br />

Sorting control line The G-13.mft is equipped, for external sorting of the cash-box<br />

coins, with a JST connector with three sorting control lines,<br />

via which the → sorting gates are addressed. These<br />

bidirectional lines can also send "Full" signals in the other<br />

direction to the G-13.mft so that coins are directed into the<br />

cash-box and no longer to an external sorting device. With<br />

the G-13.mft with parallel interface, the → return signal line<br />

can also be used on an alternative basis for the purpose of<br />

sorting.<br />

The G-13.mft with cctalk interface is equipped, for external<br />

sorting of cash-box coins, with a 10-pole connecting plug<br />

with six sorting control lines, via which the eight cctalk sorter<br />

pathes are addressed and the → sorting gates actuated.<br />

Sorting gate The sorting gates are activated depending on the run time of<br />

the accepted coins in the G-13.mft and direct the coins to be<br />

sorted into the return area or coin outlet of the coin validator.<br />

Sorting time The sorting time specifies the switching times of an external<br />

sorting device.<br />

Switching block The G-13.mft has two switching blocks with ten DIL switches<br />

(S1.1–10 and S2.1–10) each. Functions that can be switched<br />

on site are assigned to the individual switches (see separate<br />

instructions for the G-13.mft).<br />

Teach mode In the teach mode the last eight → coin channels<br />

(= teach channels) can be assigned new coin types or tokens<br />

on site on the vending machine, which means that these<br />

newly configured coins are accepted in the respective coin<br />

channel. With <strong>WinEMP</strong> the teach mode can either be switched<br />

off entirely or limited to fewer teach channels.<br />

Timed-output mode If a game is not to be activated via a short signal but rather via<br />

a constant time signal in the TV totalizer operation of the<br />

G-13.mft → totalizer, you can (in the timed-output mode, can<br />

be activated in <strong>WinEMP</strong>) use the totalizer's lower switching<br />

block to set a certain period of time.<br />