144<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

Error message Description Cause Remedy<br />

Data block download<br />

WRONG LIMITS (CHANNEL<br />

X, MEASUREMENT X)!<br />

WRITE DATA INTO<br />

VALIDATOR<br />

NEVERTHELESS?<br />

NO CURRENT EURO DATA<br />

BLOCK!<br />

<strong>WinEMP</strong> discovers faulty actual<br />

data<br />

<strong>WinEMP</strong> searches for Euro<br />

values in the actual data block<br />

(set) entered<br />

NO EURO DATA BLOCK! <strong>WinEMP</strong> searches for Euro<br />

values in the new data block<br />

(set) entered<br />

EURO DATA ERROR! <strong>WinEMP</strong> searches for Euro<br />

values in the actual/new data<br />

block (set) entered<br />

VALIDATOR CANNOT BE<br />

PROGRAMMED TO EURO!<br />

ERROR WHEN WRITING<br />

THE DATA INTO VALIDATOR!<br />

Selecting the function "Data<br />

block download" not possible<br />

<strong>WinEMP</strong> cannot read data<br />

block data of the connected<br />

coin validator<br />

<strong>WinEMP</strong> cannot establish<br />

connection to the connected<br />

coin validator<br />

Actual data differs from the default<br />

values on the label of the coin validator<br />

Data block (set) should include Euro<br />

values. However, <strong>WinEMP</strong> does not find<br />

any<br />

Data block (set) should include Euro<br />

values. However, <strong>WinEMP</strong> does not find<br />

any<br />

Actual data block (set) should include<br />

Euro values. However, <strong>WinEMP</strong> does<br />

not find any<br />

New data block (set) should include<br />

Euro values. However, <strong>WinEMP</strong> does<br />

not find any<br />

Chip card inserted does not provide<br />

access authorization<br />

Invalid device number or data<br />

Connection to the coin validator<br />

interrupted<br />

Configure default values from the label<br />

of the coin validator first and then<br />

repeat process (see Chap. 8<br />

"Configuration")<br />

Configure default values from the label<br />

of the coin validator first and then<br />

repeat process (see Chap. 8<br />

"Configuration")<br />

Contact <strong>NRI</strong><br />

Configure default values from the label<br />

of the coin validator first and then<br />

repeat process (see Chap. 8<br />

"Configuration")<br />

Contact <strong>NRI</strong><br />

Repeat process with appropriately<br />

programmed chip card<br />

Contact <strong>NRI</strong><br />

Check connection to the coin validator<br />

(see Chap. 3 ”Installation”)<br />

STATUS AND ERROR MESSAGES<br />

<strong>WinEMP</strong> – G-13.mft