National Rejectors, Inc. GmbH, Buxtehude<br />

141<br />

Error message Description Cause Remedy<br />

Acceptance band<br />

adjustment<br />

PLEASE INSERT THE<br />

GENUINE COINS FIRST!<br />

CHANNEL X IS NOT<br />

OCCUPIED! ACCEPTANCE<br />

BAND CANNOT BE<br />

ADJUSTED<br />

NO COIN ACCEPTED IN<br />

CHANNEL X! ACCEPTANCE<br />

BAND OF THIS CHANNEL<br />

CANNOT BE ADJUSTED<br />

ACCEPTANCE BAND<br />

CANNOT BE ADJUSTED<br />

Settings<br />

NO ACCESS RIGHTS!<br />

CHANGES WILL BE<br />

IGNORED<br />

ENTRIES NOT CORRECT!<br />

IGNORE CHANGES?<br />

SORTING NOT CORRECT!<br />

IGNORE CHANGES?<br />

COIN VALUE NOT<br />

CORRECT! IGNORE<br />

CHANGES?<br />

Acceptance band adjustment<br />

started with the insertion of<br />

false coins<br />

The acceptance band of the<br />

selected coin channel cannot<br />

be adjusted<br />

The acceptance band of the<br />

selected coin channel cannot<br />

be adjusted<br />

The acceptance band of the<br />

selected coin channel cannot<br />

be adjusted<br />

Entries on the screen "Settings"<br />

are not written into the<br />

connected coin validator<br />

Entries on the screen "Settings"<br />

are incorrect and should not be<br />

written into the connected coin<br />

validator<br />

Entry for sorting on the screen<br />

"Settings" is incorrect and<br />

should not be written into the<br />

connected coin validator<br />

Entry for coin value on the<br />

screen "Settings" is incorrect<br />

and should not be written into<br />

the connected coin validator<br />

Acceptance band adjustment must be<br />

started with the insertion of genuine<br />

coins<br />

This coin channel has not been<br />

assigned to a coin type<br />

This coin channel has been assigned to<br />

a different coin type than the coin type<br />

inserted or has not been assigned to any<br />

coin type<br />

Insert appropriate genuine coins first<br />

(see Chap. 8 "Configuration")<br />

Select coin channel which displays an<br />

acceptance of at least 80% (see<br />

Chap. 8 "Configuration")<br />

Select coin channel which displays an<br />

acceptance of at least 80% (see<br />

Chap. 8 "Configuration")<br />

Measured values are contradictory Insert appropriate coins again and<br />

repeat process (see Chap. 8<br />

"Configuration")<br />

Chip card inserted does not provide<br />

access authorization<br />

Incorrect entry (entries) on the screen<br />

"Settings"<br />

Incorrect entry for sorting on the screen<br />

"Settings"<br />

Incorrect entry for coin value on the<br />

screen "Settings"<br />

Repeat process with appropriately<br />

programmed chip card<br />

Cancel changes and, if necessary,<br />

enter the values again (see Chap. 8<br />

"Configuration")<br />

Cancel changes and, if necessary,<br />

configure sorting again (see Chap. 8<br />

"Configuration")<br />

Cancel changes and, if necessary,<br />

configure coin value again (see<br />

Chap. 8 "Configuration")<br />

<strong>WinEMP</strong> – G-13.mft STATUS AND ERROR MESSAGES