WinEMP - NRI
WinEMP - NRI
WinEMP - NRI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
National Rejectors, Inc. GmbH, Buxtehude<br />
141<br />
Error message Description Cause Remedy<br />
Acceptance band<br />
adjustment<br />
PLEASE INSERT THE<br />
GENUINE COINS FIRST!<br />
CHANNEL X IS NOT<br />
OCCUPIED! ACCEPTANCE<br />
BAND CANNOT BE<br />
ADJUSTED<br />
NO COIN ACCEPTED IN<br />
CHANNEL X! ACCEPTANCE<br />
BAND OF THIS CHANNEL<br />
CANNOT BE ADJUSTED<br />
ACCEPTANCE BAND<br />
CANNOT BE ADJUSTED<br />
Settings<br />
NO ACCESS RIGHTS!<br />
CHANGES WILL BE<br />
IGNORED<br />
ENTRIES NOT CORRECT!<br />
IGNORE CHANGES?<br />
SORTING NOT CORRECT!<br />
IGNORE CHANGES?<br />
COIN VALUE NOT<br />
CORRECT! IGNORE<br />
CHANGES?<br />
Acceptance band adjustment<br />
started with the insertion of<br />
false coins<br />
The acceptance band of the<br />
selected coin channel cannot<br />
be adjusted<br />
The acceptance band of the<br />
selected coin channel cannot<br />
be adjusted<br />
The acceptance band of the<br />
selected coin channel cannot<br />
be adjusted<br />
Entries on the screen "Settings"<br />
are not written into the<br />
connected coin validator<br />
Entries on the screen "Settings"<br />
are incorrect and should not be<br />
written into the connected coin<br />
validator<br />
Entry for sorting on the screen<br />
"Settings" is incorrect and<br />
should not be written into the<br />
connected coin validator<br />
Entry for coin value on the<br />
screen "Settings" is incorrect<br />
and should not be written into<br />
the connected coin validator<br />
Acceptance band adjustment must be<br />
started with the insertion of genuine<br />
coins<br />
This coin channel has not been<br />
assigned to a coin type<br />
This coin channel has been assigned to<br />
a different coin type than the coin type<br />
inserted or has not been assigned to any<br />
coin type<br />
Insert appropriate genuine coins first<br />
(see Chap. 8 "Configuration")<br />
Select coin channel which displays an<br />
acceptance of at least 80% (see<br />
Chap. 8 "Configuration")<br />
Select coin channel which displays an<br />
acceptance of at least 80% (see<br />
Chap. 8 "Configuration")<br />
Measured values are contradictory Insert appropriate coins again and<br />
repeat process (see Chap. 8<br />
"Configuration")<br />
Chip card inserted does not provide<br />
access authorization<br />
Incorrect entry (entries) on the screen<br />
"Settings"<br />
Incorrect entry for sorting on the screen<br />
"Settings"<br />
Incorrect entry for coin value on the<br />
screen "Settings"<br />
Repeat process with appropriately<br />
programmed chip card<br />
Cancel changes and, if necessary,<br />
enter the values again (see Chap. 8<br />
"Configuration")<br />
Cancel changes and, if necessary,<br />
configure sorting again (see Chap. 8<br />
"Configuration")<br />
Cancel changes and, if necessary,<br />
configure coin value again (see<br />
Chap. 8 "Configuration")<br />
<strong>WinEMP</strong> – G-13.mft STATUS AND ERROR MESSAGES