WinEMP - NRI
WinEMP - NRI
WinEMP - NRI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
140<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
Error message Description Cause Remedy<br />
Main menu<br />
ERR67 -<br />
MEASURING TIME<br />
EXCEEDED<br />
ERR68 -<br />
FAULT IN ACCEPTANCE<br />
GATE<br />
ERR69 -<br />
STRING MANIPULATION<br />
ERR70 -<br />
COMMON INHIBIT<br />
ERR72 -<br />
INHIBIT VIA<br />
SWITCHING BLOCK<br />
ERR73 -<br />
INHIBIT VIA INDIVIDUAL<br />
INHIBIT SIGNAL LINE<br />
Coin has not passed through<br />
measurement section in the<br />
specified period of time<br />
Coin was accepted but did not<br />
get to the coin sensor (CP3<br />
sensor)<br />
Coin inserted on a string was<br />
pulled up again<br />
Coin or foreign particle in coin runway<br />
Coin runway soiled<br />
Preset attraction time too short<br />
Acceptance gate blocked or defective<br />
CP3 sensor defective<br />
CP4 sensor became active after CP3<br />
sensor<br />
Coin was rejected Coin inhibited by the vending machine<br />
via external common inhibit signal line<br />
Coin was rejected Coin inhibited via its assigned DIL<br />
switches (switches set to ON)<br />
Coin was rejected Coin inhibited by the vending machine<br />
via external individual inhibit signal line<br />
Remove coin or foreign particle<br />
Clean the flight deck (see separate<br />
instructions for the coil validator)<br />
If necessary, increase attraction time<br />
in <strong>WinEMP</strong> (see Chap. 8<br />
"Configuration")<br />
Check acceptance gate or test with<br />
<strong>WinEMP</strong> (see Chap. 6 "Preparation")<br />
Check CP3 sensor (service)<br />
If necessary, cancel inhibit via vending<br />
machine control system or tester<br />
If necessary, cancel inhibit by setting<br />
the switch to OFF or assign other coin<br />
type to this switch in <strong>WinEMP</strong> (see<br />
Chap. 8 "Configuration")<br />
If necessary, cancel inhibit via vending<br />
machine control system or assign<br />
other coin type to this signal line in<br />
<strong>WinEMP</strong> (see Chap. 8 "Configuration")<br />
STATUS AND ERROR MESSAGES<br />
<strong>WinEMP</strong> – G-13.mft