138<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

Error message Description Cause Remedy<br />

Main menu<br />

ERR12 -<br />

OPERATING VOLTAGE TOO<br />

HIGH<br />

ERR14 -<br />

CP4 SENSOR ACTIVE<br />

ERR16 -<br />

CP3 SENSOR ACTIVE<br />

ERR17 -<br />

CP SENSOR(S) ACTIVE<br />

DUE TO EXTERNAL LIGHT<br />

ERR27 -<br />

ENFORCED BREAK DUE TO<br />

STRING RECOGNITION<br />

ERR32 -<br />

LS SENSOR(S) ACTIVE<br />

DUE TO EXTERNAL LIGHT<br />

No signal from accepted coin<br />

sensor (CP4 sensor)<br />

No signal from accepted coin<br />

sensor (CP3 sensor)<br />

Continuous signal on one or<br />

both CP sensors<br />

Coin acceptance inhibited for<br />

30 seconds following string<br />

manipulation<br />

Continuous signal on one or<br />

both CP sensors of the optical<br />

diameter measurement system<br />

(LS1/LS2)<br />

Operating voltage > 18 V<br />

CP4 sensor blocked or soiled<br />

CP4 sensor defective<br />

CP3 sensor blocked or soiled<br />

CP3 sensor defective<br />

External light disturbs sensor(s)<br />

Sensor(s) defective<br />

Free CP4 sensor from foreign particles<br />

or clean<br />

Replace CP4 sensor (service)<br />

Free CP3 sensor from foreign particles<br />

or clean<br />

Replace CP3 sensor (service)<br />

Install printed-circuit board cover<br />

Check sensor(s) (service)<br />

CP4 sensor became active at rest Wait 30 seconds or perform power-on<br />

reset<br />

External light disturbs sensor(s)<br />

Sensor(s) defective<br />

Install printed-circuit board cover<br />

Check sensor(s) (service)<br />