WinEMP - NRI
WinEMP - NRI
WinEMP - NRI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
138<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
Error message Description Cause Remedy<br />
Main menu<br />
ERR12 -<br />
OPERATING VOLTAGE TOO<br />
HIGH<br />
ERR14 -<br />
CP4 SENSOR ACTIVE<br />
ERR16 -<br />
CP3 SENSOR ACTIVE<br />
ERR17 -<br />
CP SENSOR(S) ACTIVE<br />
DUE TO EXTERNAL LIGHT<br />
ERR27 -<br />
ENFORCED BREAK DUE TO<br />
STRING RECOGNITION<br />
ERR32 -<br />
LS SENSOR(S) ACTIVE<br />
DUE TO EXTERNAL LIGHT<br />
No signal from accepted coin<br />
sensor (CP4 sensor)<br />
No signal from accepted coin<br />
sensor (CP3 sensor)<br />
Continuous signal on one or<br />
both CP sensors<br />
Coin acceptance inhibited for<br />
30 seconds following string<br />
manipulation<br />
Continuous signal on one or<br />
both CP sensors of the optical<br />
diameter measurement system<br />
(LS1/LS2)<br />
Operating voltage > 18 V<br />
CP4 sensor blocked or soiled<br />
CP4 sensor defective<br />
CP3 sensor blocked or soiled<br />
CP3 sensor defective<br />
External light disturbs sensor(s)<br />
Sensor(s) defective<br />
Free CP4 sensor from foreign particles<br />
or clean<br />
Replace CP4 sensor (service)<br />
Free CP3 sensor from foreign particles<br />
or clean<br />
Replace CP3 sensor (service)<br />
Install printed-circuit board cover<br />
Check sensor(s) (service)<br />
CP4 sensor became active at rest Wait 30 seconds or perform power-on<br />
reset<br />
External light disturbs sensor(s)<br />
Sensor(s) defective<br />
Install printed-circuit board cover<br />
Check sensor(s) (service)<br />
STATUS AND ERROR MESSAGES<br />