DATA BLOCK DOWNLOAD 128 WinEMP – G-13.mft ACCEPT AB = acceptance band will be accepted from coin configuration of current data block UPDATE AB = acceptance band will be accepted from coin configuration of current data block, but its limits will be updated according to current NRI values TOKEN AB CANNOT BE PROGRAMMED = acceptance band for token cannot be programmed In most cases the new data block is to be loaded into the G-13.mft as specified in the last two columns by WinEMP. But you can also accept the current channel data configured for the new data block or configure the coin channel data without acceptance bands (see section "Configure download data" in this chapter). If you have selected a data block with the write protection activated (ATTENTION!!! WRITE PROTECTION WILL BE ACTIVATED), no more setting can be changed, thus no more data block download can be carried out either. If a NEW DATA BLOCK is equal to a CURRENT DATA BLOCK, a request appears asking whether the COMPLETE DATA BLOCK or only new ACCEPTANCE BANDS are to be loaded. Select the second answer and confirm with OK if you only want to save new acceptance limits and all the other customized settings are to remain intact; Select the first answer if you not only want to save new acceptance limits but also want to overwrite all the other settings with the default values of that data block. 4 Confirm settings with OK. Following expiry of the status bar indication, the data block download has been completed. The G-13.mft now has the new data at its disposal for coin acceptance and possibly also for the purpose of further processing the coins. 5 Check all the settings (channel-specific and channel-superordinate ones) of the new data block (see next section). Please make a note of the new data block number on the coin validator, so that you are able to find the data block number at any time independently of WinEMP. National Rejectors, Inc. GmbH, Buxtehude

WinEMP – G-13.mft After the data block download ... After a data block download you should always check whether the G-13.mft accepts inserted coins according to your requirements. For this purpose, remain in the main menu and insert coins. WinEMP indicates in which coin channel the coin was accepted (LAST CHANNEL). National Rejectors, Inc. GmbH, Buxtehude Please check coin acceptance with both memory blocks and make sure, that the correct block is selected. DATA BLOCK DOWNLOAD 129

<strong>WinEMP</strong> – G-13.mft<br />

After the data block download ...<br />

After a data block download you should always<br />

check whether the G-13.mft accepts inserted<br />

coins according to your requirements. For this<br />

purpose, remain in the main menu and insert<br />

coins. <strong>WinEMP</strong> indicates in which coin channel<br />

the coin was accepted (LAST CHANNEL).<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

Please check coin acceptance with both<br />

memory blocks and make sure, that the<br />

correct block is selected.<br />