128<br />

<strong>WinEMP</strong> – G-13.mft<br />

ACCEPT AB = acceptance band will be accepted from coin<br />

configuration of current data block<br />

UPDATE AB = acceptance band will be accepted from coin<br />

configuration of current data block, but its limits<br />

will be updated according to current <strong>NRI</strong> values<br />

TOKEN AB CANNOT BE PROGRAMMED = acceptance band for token cannot be<br />

programmed<br />

In most cases the new data block is to be loaded into the G-13.mft as<br />

specified in the last two columns by <strong>WinEMP</strong>. But you can also<br />

accept the current channel data configured for the new data block or<br />

configure the coin channel data without acceptance bands<br />

(see section "Configure download data" in this chapter).<br />

If you have selected a data block with the write protection<br />

activated (ATTENTION!!! WRITE PROTECTION WILL BE ACTIVATED), no<br />

more setting can be changed, thus no more data block<br />

download can be carried out either.<br />

If a NEW DATA BLOCK is equal to a CURRENT DATA BLOCK, a request<br />

appears asking whether the COMPLETE DATA BLOCK or only new<br />

ACCEPTANCE BANDS are to be loaded. Select the second answer and<br />

confirm with OK if you only want to save new acceptance limits and<br />

all the other customized settings are to remain intact;<br />

Select the first answer if you not only want to save new acceptance<br />

limits but also want to overwrite all the other settings with the default<br />

values of that data block.<br />

4 Confirm settings with OK.<br />

Following expiry of the status bar indication, the data block download has<br />

been completed. The G-13.mft now has the new data at its disposal for coin<br />

acceptance and possibly also for the purpose of further processing the<br />

coins.<br />

5 Check all the settings (channel-specific and channel-superordinate<br />

ones) of the new data block (see next section).<br />

Please make a note of the new data block number on the coin<br />

validator, so that you are able to find the data block number at any<br />

time independently of <strong>WinEMP</strong>.<br />

National Rejectors, Inc. GmbH, Buxtehude