WinEMP - NRI
WinEMP - NRI WinEMP - NRI
DATA BLOCK DOWNLOAD 126 c2 From the pull-down menu select the COUNTRY, in which the coin validator will be used. On the left-hand side all of the data blocks available for the country selected are listed. WinEMP – G-13.mft c3 Click a DATA BLOCK. For control purposes, the right-hand side shows each coin type assigned to a coin channel (E = coin stored with narrow acceptance band, S = coin stored with very narrow acceptance band, N/ NN/N1 = new/newer/ newest coin of one type, A or no comment = old coin of one type). (Also cp. section "Useful help for data block selection" in this chapter) c4 Confirm the data block selected with OK. The box closes and the data block is accepted as new data block in the right-hand column. National Rejectors, Inc. GmbH, Buxtehude
WinEMP – G-13.mft National Rejectors, Inc. GmbH, Buxtehude DATA BLOCK DOWNLOAD 3 Confirm your entries with OK. A dialog box opens. The second and third columns indicate the coins and acceptance band status of the current channel data. The last two columns show the coins and details for generating the acceptance bands of the new data block selected: 1 2 3 4 5 1 Memory block 0 or 1/coin channel number 2 Coin type currently configured in that coin channel 3 Acceptance band status of the relevant coin channel: ACTIVE = Acceptance band of the relevant coin is configured, coin is accepted in this channel INACTIVE = No acceptance band configured, this channel does not accept any coin 4 Coin that is to be configured in the relevant coin channel by means of a download TM/TK = Teach mode, coin channel is prepared by the manufacturer, so that new coins can be taught at the machine E = Load coin with narrow acceptance band S = Load coin with very narrow acceptance band N/NN/N1= New/newer/the newest coin of one type A = Old coin of one type 5 Information on acceptance band that is to be configured in the relevant coin channel by means of a download (can be changed to a limited extent, see section "Configure download data" in this chapter): RE-CALCULATE AB WITH REF. DATA = newest reference data factory programming (AB = acceptance band) DO NOT PROGRAM ANY AB = acceptance band is not to/cannot be programmed and must be taught by inserting coins, if necessary (e.g. of teach channels, make a note for later on where required) 127
- Page 75 and 76: WinEMP - G-13.mft CONFIGURATION - F
- Page 77 and 78: WinEMP - G-13.mft CONFIGURATION - F
- Page 79 and 80: WinEMP - G-13.mft CONFIGURATION - F
- Page 81 and 82: WinEMP - G-13.mft CONFIGURATION - F
- Page 83 and 84: WinEMP - G-13.mft CONFIGURATION - F
- Page 85 and 86: WinEMP - G-13.mft CONFIGURATION - F
- Page 87 and 88: WinEMP - G-13.mft CONFIGURATION - F
- Page 89 and 90: WinEMP - G-13.mft CONFIGURATION - F
- Page 91 and 92: WinEMP - G-13.mft CONFIGURATION - F
- Page 93 and 94: WinEMP - G-13.mft CONFIGURATION - F
- Page 95 and 96: WinEMP - G-13.mft CONFIGURATION - F
- Page 97 and 98: WinEMP - G-13.mft CONFIGURATION - F
- Page 99 and 100: WinEMP - G-13.mft CONFIGURATION - F
- Page 101 and 102: WinEMP - G-13.mft CONFIGURATION - F
- Page 103 and 104: WinEMP - G-13.mft CONFIGURATION - F
- Page 105 and 106: WinEMP - G-13.mft CONFIGURATION - F
- Page 107 and 108: WinEMP - G-13.mft CONFIGURATION - F
- Page 109 and 110: WinEMP - G-13.mft CONFIGURATION - F
- Page 111 and 112: WinEMP - G-13.mft CONFIGURATION - F
- Page 113 and 114: WinEMP - G-13.mft CONFIGURATION - F
- Page 115 and 116: WinEMP - G-13.mft Copy and paste or
- Page 117 and 118: WinEMP - G-13.mft Change token/coin
- Page 119 and 120: WinEMP - G-13.mft National Rejector
- Page 121 and 122: WinEMP - G-13.mft National Rejector
- Page 123 and 124: WinEMP - G-13.mft National Rejector
- Page 125: WinEMP - G-13.mft National Rejector
- Page 129 and 130: WinEMP - G-13.mft After the data bl
- Page 131 and 132: WinEMP - G-13.mft National Rejector
- Page 133 and 134: WinEMP - G-13.mft 10 Restore G-13.m
- Page 135 and 136: WinEMP - G-13.mft WINEMP UPDATE 12
- Page 137 and 138: National Rejectors, Inc. GmbH, Buxt
- Page 139 and 140: National Rejectors, Inc. GmbH, Buxt
- Page 141 and 142: National Rejectors, Inc. GmbH, Buxt
- Page 143 and 144: National Rejectors, Inc. GmbH, Buxt
- Page 145 and 146: National Rejectors, Inc. GmbH, Buxt
- Page 147 and 148: WinEMP - G-13.mft C Card reader 10
- Page 149 and 150: WinEMP - G-13.mft E ECV 155 totaliz
- Page 151 and 152: WinEMP - G-13.mft Return signal lin
- Page 153 and 154: WinEMP - G-13.mft Glossary National
- Page 155 and 156: WinEMP - G-13.mft National Rejector
- Page 157 and 158: WinEMP - G-13.mft National Rejector
DATA BLOCK DOWNLOAD<br />
126<br />
c2 From the pull-down<br />
menu select the<br />
COUNTRY, in which the<br />
coin validator will be<br />
used.<br />
On the left-hand side<br />
all of the data blocks<br />
available for the<br />
country selected are<br />
listed.<br />
<strong>WinEMP</strong> – G-13.mft<br />
c3 Click a DATA BLOCK.<br />
For control purposes,<br />
the right-hand side<br />
shows each coin type<br />
assigned to a coin<br />
channel (E = coin<br />
stored with narrow<br />
acceptance band,<br />
S = coin stored with<br />
very narrow<br />
acceptance band, N/<br />
NN/N1 = new/newer/<br />
newest coin of one<br />
type, A or no<br />
comment = old coin<br />
of one type).<br />
(Also cp. section<br />
"Useful help for data<br />
block selection" in this<br />
chapter)<br />
c4 Confirm the data block selected with OK.<br />
The box closes and the data block is accepted as new data block in<br />
the right-hand column.<br />
National Rejectors, Inc. GmbH, Buxtehude