<strong>WinEMP</strong> – G-13.mft<br />
Copy and paste or delete coin channel data<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
CONFIGURATION<br />
If the acceptance band and all the other assigned properties of a coin<br />
channel are to be copied and pasted in another coin channel:<br />
1 Mark the coin channel with the desired settings by clicking the<br />
respective CHANNEL NUMBER button.<br />
The data of the coin channel will be backlit darker.<br />
2 Copy the data of the marked channel by clicking the menu item<br />
CHANNEL and then COPY.<br />
The channel is provided with a rhombus symbol next to the channel<br />
number (= all coin channel data stored in the clipboard).<br />
3 Mark the coin channel for the same settings by clicking the<br />
respective CHANNEL NUMBER button.<br />
The data of the coin channel will then be backlit darker.<br />
4 Insert the copied channel data into the marked coin channel by<br />
clicking the menu item CHANNEL and then PASTE.<br />
The new data is then stored in <strong>WinEMP</strong>, whereby any existing data is<br />
overwritten, if necessary.<br />
5 Leave the info box with the <strong>WinEMP</strong> standard setting and close the<br />
box with OK (if you like to change the acceptance bandwidth, please<br />
use the coin insertion function and follow the steps listed in section<br />
"Optimize acceptance of genuine coins and rejection of false coins"<br />
in this chapter).<br />
The acceptance band of the coin channel just configured can now be<br />
adjusted, e.g., for a narrow or very narrow coin channel (see section<br />
"Optimize acceptance of genuine coins and rejection of false coins" in this<br />
chapter). Please refer to section "Configure G-13.mft for parallel standard/<br />
Casino/totalizer or MDB/S1/cctalk operation" in this chapter to find how to<br />
change other coin channel data.<br />
6 Click BACK to store the setting in the G-13.mft or proceed to the next<br />
setting on this screen and store all your settings later.<br />