CONFIGURATION – FOR CCTALK INTERFACE<br />

Specify sorting time<br />

114<br />

<strong>WinEMP</strong> – G-13.mft<br />

Now that you have just defined via which sorting control line and sorter path<br />

the respective coin type will be sorted, the sorting time now has to be set as<br />

the switching time for the external sorting device:<br />

1 Select menu item EXTRA and then OPTIONS.<br />

The dialog box BASIC SETTINGS AND OPTIONS opens.<br />

2 In the "table of<br />

contents" on<br />

the left-hand<br />

side, select<br />

the index word<br />

SORTING.<br />

3 On the righthand<br />

side<br />

under SORTING<br />

CONTROL, enter<br />

the desired<br />

PERIOD using<br />

the keyboard.<br />

The sorting time can be 300 to 1000 ms and is converted into 4-ms<br />

increments. A time of 500 ms should be set for the <strong>NRI</strong> sorting<br />

device.<br />

4 Confirm your entry with OK and close the window again or proceed<br />

to the next setting in this dialog box first and confirm all your settings<br />

later.<br />

5 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />

National Rejectors, Inc. GmbH, Buxtehude