CONFIGURATION – FOR CCTALK INTERFACE 112 WinEMP – G-13.mft If you want to assign specific control lines to the sorter pathes: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word SORTING. 3 On the righthand side under SORTING CONTROL in the line of the respective SORTER PATH, click on (tick) the box of the OUTPUT LINE(S) that is (are) to transmit a sorting signal (here: NRI 3-fold sorting device). If you click on the box again the tick would be deleted, and no signal would be transmitted on this line. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. National Rejectors, Inc. GmbH, Buxtehude

WinEMP – G-13.mft CONFIGURATION – FOR CCTALK INTERFACE Assign sorter path to a coin type After you have defined the output lines for the cctalk sorter path, you must now assign a specific sorter path to the coin types to be sorted, i.e. to the cctalk output 1–16: 1 Select menu item EXTRA and then OPTIONS. The dialog box BASIC SETTINGS AND OPTIONS opens. 2 In the "table of contents" on the left-hand side, select the index word SORTING. 3 On the righthand side under SORTER PATH in the line of the respective CCTALK OUTPUT, select SORTER PATH 1-8 from the pull-down menu (here: NRI 3-fold sorting device). National Rejectors, Inc. GmbH, Buxtehude Next to DEFAULT/OVERRIDE, select the sorter path for the cash-box chute or for the alternative sorter path which is to be used to sort coins when a payout unit is full. 4 Confirm your entry with OK and close the window again or proceed to the next setting in this dialog box first and confirm all your settings later. 5 Click BACK to store the setting in the G-13.mft or proceed to the next setting on this screen and store all your settings later. 113

<strong>WinEMP</strong> – G-13.mft CONFIGURATION – FOR CCTALK INTERFACE<br />

Assign sorter path to a coin type<br />

After you have defined the output lines for the cctalk sorter path, you must<br />

now assign a specific sorter path to the coin types to be sorted, i.e. to the<br />

cctalk output 1–16:<br />

1 Select menu item EXTRA and then OPTIONS.<br />

The dialog box BASIC SETTINGS AND OPTIONS opens.<br />

2 In the "table of<br />

contents" on<br />

the left-hand<br />

side, select<br />

the index word<br />

SORTING.<br />

3 On the righthand<br />

side<br />

under SORTER<br />

PATH in the line<br />

of the<br />

respective<br />

CCTALK OUTPUT,<br />

select SORTER<br />

PATH 1-8 from the pull-down menu (here: <strong>NRI</strong> 3-fold sorting device).<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

Next to DEFAULT/OVERRIDE, select the sorter path for the cash-box<br />

chute or for the alternative sorter path which is to be used to sort<br />

coins when a payout unit is full.<br />

4 Confirm your entry with OK and close the window again or proceed<br />

to the next setting in this dialog box first and confirm all your settings<br />

later.<br />

5 Click BACK to store the setting in the G-13.mft or proceed to the next<br />

setting on this screen and store all your settings later.<br />