. Technical data<br />

Type (E / KU / KE):<br />

<strong>STA</strong> 1 1 -<br />

1<br />

100%<br />

14 – Sectional door operator <strong>STA</strong> 1 / Rev. 0.2<br />

<strong>STA</strong> 1<br />

12-1<br />

100%<br />

<strong>STA</strong> 1<br />

11-24<br />

100%<br />

<strong>STA</strong> 1<br />

10- 0<br />

100%<br />

Driving torque (Nm): 130 120 110 100 70<br />

Maximum safety catch torque<br />

(Nm):<br />

<strong>STA</strong>W 1<br />

-1<br />

- - - - -<br />

Permissible torque (Nm): - - - - -<br />

Driving motor speed (min -1): 15 19 24 30 19<br />

Motor output (kw): 0,55 0,55 0,55 0,55 0,37<br />

Operating voltage (V): 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ 230 / 1~<br />

Mains frequency Hz: 50 50 50 50 50<br />

Control voltage: (V): 24 24 24 24 24<br />

Nominal motor current (A): 2,4 1,8 1,75 1,5 4,8<br />

Motor duty cycle (%): 100 100 100 100 25<br />

Cable on site (mm 2 ): 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5 3 x 1,5<br />

Fuse protection on site (A): 10,0 10,0 10,0 10,0 10,0<br />

Protection type (IP) 54 54 54 54 54<br />

Temperature range (°C): -10 / +60 -10 / +60 -10 / +60 -10 / +60 -10 / +60<br />

Continuous sound pressure level<br />

(dB (A)):<br />

< 70 < 70 < 70 < 70 -<br />

Weight per piece (kg): 18 / 18 / 23 18 / 18 / 23 18 / 18 / 23 18 / 18 / 23 13 / 13 / 15<br />

Maximum number of<br />

revolutions of driven shaft:<br />

13 13 13 13 13<br />

Hollow shaft (mm): 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 25,4