03.03.2013 Views

Manual

Manual

Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Maintenance Instructions<br />

6.3 Environmental protection<br />

Danger to the environment due to mishandling!<br />

Significant environmental damage can occur, particularly for incorrect disposal,<br />

if environmentally hazardous operating materials are mishandled.<br />

Therefore:<br />

• Always observe the instructions mentioned below.<br />

• Take immediate action if environmentally hazardous materials<br />

reach the environment. Inform the responsible local authorities<br />

about the damage in the case of doubt.<br />

The disposal must be performed by a specialist disposal<br />

company.<br />

6.4 Maintenance interval<br />

Environmental protection.<br />

For the maintenance interval, please see the „General information for PMS generators“ which are attached to this<br />

manual.<br />

At generator with dynamic operation hours (f.e. Generators with iControl2 system) the maintenance interval can may<br />

be extended.<br />

With the dynamic operation hours the service interval can be raised up to<br />

30% (200h max.). Make sure that the dynamic operation hours are not reset<br />

accidently between the service interval.<br />

6.5 General maintenance instructions<br />

6.5.1 Checks before starting<br />

• Oil level<br />

• Cooling system leaks<br />

• Visual check for any changes, leaks oil drain system, v-belt,<br />

cable connections, hose clips, air filter, fuel lines<br />

Note:<br />

6.5.2 Hose elements and rubber formed component in the sound cover<br />

Check all hoses and hose connections for good condition. The rubber hoses are very sensitive to enviromental influences.<br />

They can season fast with dry air, in which environment of muted oil and fuel steams and increased temperature.<br />

The hoses must be checked regularly for elasticity. There are operating situations, at which the hoses must be<br />

renewed once in the year.<br />

Additionally to usual tasks of maintenance (oil level check, oil filter control etc.) further maintenance activities are to<br />

be accomplished for marine gensets. It belongs control of the sacrificial anode (cooling water connection block) and<br />

the front seal cover at the generator.<br />

7.5.12 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 97

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!