Installation Instructions<br />

Tilted position 30 degrees<br />

The distance between the hydrostatic head and the critical point at the<br />

exhaust elbow is only 216 mm. This means that in a tilted position of 30<br />

degrees you already face the highest risk of sea water sloshing into the combustion<br />

chamber.<br />

Tilted position 45 degrees<br />

The water level is now at the same height as the critical point at the exhaust<br />

elbow. If the ship is sailed in a tilted position of 45 degrees with an installation<br />

like this, the ingress of cooling water into the combustion chamber is<br />

inevitable. Irreparable damages are preprogrammed.<br />

B) Installation distance between waterlock and generator’s center line 1000 mm<br />

Fig. 5.7-5: waterlock, 1000 mm next to center line<br />

Fig. 5.7.3.2-3: Tilted position 30 degrees<br />

Fig. 5.7.3.2-4: Tilted position 45 degrees<br />

7.5.12 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 5: Installation Instructions Seite/Page 69