Installation Instructions<br />

Tilted position 30 degrees<br />

The distance of the water level, even in ideal position, changes that only 458<br />

mm distance remain. So the critical distance is under-run already.<br />

Tilted position 45 degrees<br />

In this case the water level rose so high, that the distance constitutes only<br />

325 mm.<br />

Fig. 5.7.3.1-3: Tilted position 30 degrees<br />

Fig. 5.7.3.1-4: Tilted position 45 degrees<br />

Even when the collector is mounted in the ideal spot, at an extremely tilted position of 45 degrees there is still the<br />

risk that water can get straight into the discharge stack area through strong rocking motion („sloshing“). This shows<br />

that the distance of 600 mm represents a minimum size at which, even when installed ideally, the water can slosh<br />

into the exhaust elbow when the ship is very tilted or rocks very hard.<br />

Summary:<br />

The preset minimum height of 600 mm must be regarded unconditionally and is only valid, if the waterlock is<br />

mounted in its ideal position in center underneath the generator. A higher position is highly recommended if it has to<br />

be reckoned with tilted positions of 45 degrees.<br />

7.5.12 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 5: Installation Instructions Seite/Page 67