Installation Instructions<br />
5.5.2 Scheme for Freshwater Circuit at Two Circuit Cooling System<br />
1. Expansion Tank<br />
2. Exhaust Manifold<br />
3. Thermostat Housing<br />
Fig. 5.5.2-1: Scheme for Freshwater Circuit at Two Circuit Cooling System<br />
5.6 Installation of the water cooled exhaust system<br />
5.6.1 Installation of the standard exhaust system<br />
The generator exhaust system must remain completely independent and separate from the exhaust system of any<br />
other unit(s) on board. The water lock must be installed at the lowest point of the exhaust system. An optional noise<br />
insulated water lock can also be installed. The exhaust hose descends from the capsule to the water lock. Then the<br />
hose rises via the „goose neck“ to the silencer (see drawing). The goose neck must be vertical and sit preferably<br />
along the ship's keel centre line. In order that the back pressure inside the exhaust is not to high, the total length of<br />
the exhaust system should not exceed 6,3 m.<br />
By injecting the outlet raw water into the exhaust manifold, the exhaust gases are cooled and the noise emissions<br />
from the exhaust system are reduced.<br />
Exhaust diameter see section 8.10, “Diameter of conduits,”<br />
on page 212<br />
4. Freshwater pump<br />
5. Heat Exchanger<br />
6. Cooling Water Connection Block<br />
7.5.12 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 5: Installation Instructions Seite/Page 61