5.5 Installation of the cooling system - fresh water<br />

5.5.1 Position of the external cooling water expansion tank<br />

Position of the external cooling water expansion tank<br />

The Panda generator is normally supplied with an additional, external cooling<br />

water expansion tank. This tank must be installed in such a way that its<br />

lower edge is at least 500 mm more highly arranged than the upper edge of<br />

the sound cover.<br />

If this 500 mm should be fallen below, i.e. the cooling water expansion tank<br />

is lower installed, very large problems can occur with filling and ventilating.<br />

Extend and displace the hose lines to the outside or possibly even up to the<br />

deck.<br />

The external cooling water expansion tank may be filled only<br />

up to the lower edge of the lower tension tape (see note „max“)<br />

in the maximum filling level in cold condition.<br />

Installation Instructions<br />

Fig. 5.5.1-1: Position of the External Cooling Water Expansion<br />

ATTENTION!<br />

Seite/Page 60 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 5: Installation Instructions 7.5.12<br />

Tank