The Panda Generator<br />

4.3.5 CSensors and Switches for Operation Surveillance<br />

Thermo-switch at cylinder head<br />

The thermo-switch at the cylinder head serves to monitor the generator temperature.<br />

Sample picture 4000s FC<br />

Thermo-switch at water-cooled exhaust elbow<br />

This thermo switch is located at the water-cooled exhaust<br />

elbow union and serves to monitor the temperature of the fresh<br />

water cooling system. It takes a measurement at the hottest<br />

spot, since the combustion gases are guided from the cylinder<br />

head for the exhaust elbow.<br />

Sample picture 4000s FC<br />

Thermo-switch in the generator coil<br />

1. Generator coil<br />

2. Thermo-switch<br />

3. Housing<br />

Two thermo switches are located inside the winding to protect the generator<br />

coil, which for safety reasonsare installed independently in parallel.<br />

Sample picture<br />

Fig. 4.3.5-1: TThermo-switch at cylinder head<br />

Fig. 4.3.5-2: Thermo-switch at exhaust elbow<br />

Fig. 4.3.5-3: Thermo-switch coil<br />

7.5.12 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 4: The Panda Generator Seite/Page 45<br />