• Short-term standstill (1 to 3 months).<br />

• Medium-term standstill / winter storage (3 to 6 months).<br />

• Long-term standstill (storage) / shutdown (more than 6 months).<br />

3.6.1 Reference note for the starter battery at a long-term standstill<br />

Starter batteries<br />

Self-discharge of batteries is a physical and chemical process<br />

and cannot even be avoid by disconnecting the battery.<br />

Notice:<br />

• Disconnect the battery from the generator at a long-term standstill.<br />

• Charge the battery on a regular basis. Follow the notes of the battery manufacturer.<br />

Before charging the battery, check the acid level according to the type of battery and refill each cell with distilled<br />

water up to the marking if necessary.<br />

Today’s starter batteries are normally maintenance-free.<br />

Deep discharge may damage the battery and may be useless afterwards.<br />

Keep the battery clean and dry. Continuously clean the battery terminals (+ and -) and clamps and lubricate with an<br />

acid-free and acid-resistant grease. Make sure there is a good contact of the clamp connections when assembling. If<br />

voltage is approx. below 1,95 Volt, the cell should not decline the open-circuit voltage of the battery. This equates<br />

approx. 2,1V / cell open-circuit voltage when battery is fully charged.<br />

For a 12 V battery applies 11,7 V lower open-circuit voltage (battery flat) - conservation charging 13,2 V.<br />

For a 24 V battery applies 23,4 V lower open-circuit voltage (battery flat) - conservation charging 26,4 V.<br />

These data relate to a battery temperature of 20-25°C. Consider the specifications of the battery manufacturer.<br />

Fischer Panda recommendation:<br />

• Install a battery main switch and turn it to the off-position.<br />

(Disrupt the battery circuit)<br />

• Install a sufficient fuse in the positive battery line close to the<br />

battery<br />

• Check contacts for corrosion on a regular basis.<br />

3.6.2 Arrangements at a short-term standstill<br />

Notice:<br />

Short-term standstill (1 to 3 months)<br />

• Measure the charge of battery via the open-circuit voltage<br />

• At stand still >7 days - disconnect the battery (e.g. put battery main switch to 0)<br />

• Within 2-3 months - let the engine run for at least 10 min<br />

3.6.3 Arrangements at a medium-term standstill / winter storage<br />

Medium-term stand still (3 to 6 months)<br />

3.6.3.1 Arrangements for conservation:<br />

• Check the charge of battery and recharge approximately every 3 months if necessary. Consider the specifications<br />