Discharge the capacitor - single phase<br />

01. Discharge reactor (5-10kOhm)<br />

02. Multimeter<br />

03. Capacitor<br />

Discharge the capacitor - three phase<br />

01. Discharge reactor (5-10kOhm)<br />

02. Multimeter<br />

03. Capacitor<br />

At three phase capacitors the discharge must be made<br />

between every phase (L1-L2; L2-L3; L1-L3)<br />

Checking<br />

Switch the multimeter to capacitor measuring and connect<br />

the meter end probes to the capacitor terminals. Measure<br />

capacity of the capacitor.<br />

Maintenance Instructions<br />

Fig. 6.11.2-1: Discharge capacitor single phase<br />

Fig. 6.11.2-2: Discharge capacitor three phase<br />

Fig. 6.11.2-3: Capacitor checking<br />

Check all capacitors in the electrical cabinet<br />

Test each capacitor by touching the multimeter (set on capacitor measuring) probes on the capacitor terminals:<br />

measure the capacity of the capacitors.<br />

The capacitors should not be removed from the electrical cabinet before the check is made.<br />

Checking the electrical connections to the Capacitor<br />

It must be ensured that the electrical connections to the capacitor are always tight fitting. Loose connections with<br />

transitional resistance can mean that the contact surfaces will become heated externally. This can lead to faster<br />

deterioration of the capacitors.<br />

Seite/Page 114 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions 7.5.12<br />