Maintenance Instructions<br />

Unscrew the filter element from the mount (left hand rotation).<br />

Screw the new filter element into the mount.<br />

Lubricate the sight glasses o-ring with a heat resistant grease (Specification:<br />

Antiseize) and screw the sight glass back into its mount (right hand rotation).<br />

6.11.2Check and discharge the capacitors<br />

NEVER check the capacitors whilst the generator motor is running!<br />

Charged capacitors can be lethal. Do not contact the<br />

capacitors with bare fingers or non-insulated metallic objects!<br />

In order to test the capacitors, the terminal lead wires have to<br />

be disconnected using pliers or a screwdriver with insulated<br />

handle(s). Once the wires have been removed, the capacitors<br />

must be discharged by bridging the capacitor terminals with a<br />

discharge reactor.<br />

Attention!:<br />

The capacitors can be checked using a multimeter with capacitor measuring.<br />

Fig. 6.11.1.1-3: Fuel filter<br />

Fig. 6.11.1.1-4: Fuel filter<br />

The capacitors fitted inside the cabinet are discharged over the soldered resistor at every capacitor. The discharge<br />

over the discharge reactor (see special tools) is security because the capacitor voltage is lethal.<br />