Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Do Bell Test<br />
<br />
<br />
Yes<br />
<br />
<br />
2 abc<br />
<br />
<br />
Yes<br />
<br />
<br />
Omit<br />
<br />
<br />
<br />
<br />
3 def<br />
<br />
<br />
3 def<br />
<br />
<br />
Menu<br />
Press OMIT to invoke the<br />
Engineers Hold Off mode<br />
of a Texecom Bellbox<br />
Use the SCROLL key to<br />
select the required test<br />
Press YES to test ALL<br />
channels or use keys 0 - 8<br />
to select individual channels<br />
e.g. 3 = Channel 3<br />
Press YES again to clear ALL<br />
channels or use keys 0 - 8<br />
to clear individual channels<br />
e.g. 3 = Channel 3<br />
This option allows Allows the Bell, Speaker and various<br />
control panel outputs to be tested.<br />
The following outputs can be individually tested:<br />
Test Bell The Bell output<br />
Test Strobe The Strobe output<br />
Test Speaker The Speaker output<br />
Test Digi The Hardwired digicom outputs<br />
Test Panel The panel outputs<br />
Test RedCARE The plug on RedCARE outputs<br />
Test Com???? The plug on digi outputs<br />
LCD Display The LCD keypad display<br />
User Outputs Any outputs that have the ‘User Test’<br />
attribute (see page 62 for details).<br />
<br />
Pressing OMIT at the Bell or Strobe Test will cause the<br />
Strobe output to pulse 3 times, invoking Engineers<br />
Hold Off mode if a Texecom bell box is connected.<br />
Do Walk Test<br />
<br />
<br />
<br />
<br />
86 INS176<br />
Yes<br />
<br />
<br />
2 abc<br />
Yes<br />
<br />
<br />
Yes<br />
<br />
Chime<br />
<br />
<br />
Area<br />
<br />
<br />
???<br />
<br />
<br />
Menu<br />
Press YES to walk test all<br />
areas or use keys 1 - 8<br />
to select/deselect areas<br />
Press CHIME to select:<br />
Chime Once then lockout zone<br />
Chime on every activation<br />
or No Chime at all<br />
Press AREA. to toggle the<br />
display between the zones<br />
that have been tested and<br />
the zones that still need testing<br />
To view zones that have not<br />
activated recently, enter<br />
the<br />
number of days required<br />
i.e. 007 will show zones that have<br />
not activated in the last 7 days<br />
Any of the zones on the system can be walk tested to ensure<br />
that they operate correctly. A walk test can only be performed<br />
when the system or area is disarmed.<br />
<br />
Once a zone has been activated it will not generate a<br />
chime tone again. If however the key is pressed, a<br />
zone will chime every time it is activated.<br />
The Walk test menu also includes a last activation log that<br />
can be recalled when doing a walk test. This log shows zones<br />
that have NOT been activated over a period of days.<br />
Pressing the key will firstly show the zones that still need<br />
testing, pressing the key a second time will display the<br />
zones that have not been activated that day, to view zones<br />
that have not been activated for 3 days, type in 003 the<br />
maximum number of days that can be recalled is 255,<br />
pressing the key a third time will revert back to the<br />
standard walk test display.