Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Non-Zone Event Types<br />
The default Non-Zone Event codes are as follows:<br />
No Type Event Reporting Group Contact ID SIA ID<br />
20 Keypad Medical Alarm Priority Alarm 100 MA Keypad No *<br />
Restore Restore 100 MH Keypad No *<br />
21 Keypad Fire Alarm Priority Alarm 115 FA Keypad No *<br />
Restore Restore 115 FH Keypad No *<br />
22 Keypad Audible PA Alarm Priority Alarm 120 PA Keypad No *<br />
Restore Restore 120 PH Keypad No *<br />
23 Duress Code Alarm Alarm Priority Alarm 122 HA User No<br />
Restore Restore 122 HH User No<br />
24 Keypad Silent PA Alarm Priority Alarm 121 PA Keypad No *<br />
Restore Restore 121 PH Keypad No *<br />
25 Alarm Active Alarm - - - -<br />
Restore - - - -<br />
26 Bell Active Alarm - - - -<br />
Restore - - - -<br />
27 Re-arm Alarm Alarm - - Zone No<br />
Restore - - - -<br />
28 Verified Cross Zone Alarm Alarm Alarm 130 BV 00<br />
Restore - - - -<br />
29 User Code Alarm - - - User No<br />
Restore - - - -<br />
30 Exit Started Alarm - - - Keypad No<br />
Restore - - - -<br />
31 Exit Error (Arming Failed) Alarm Open/Close 457 EE 00<br />
Restore - - - -<br />
32 Entry Started Alarm - - - -<br />
Restore - - - -<br />
33 Area Arm Suite Alarm Open/Close - - Suite No 1 - 8<br />
Restore Open/Close - - -<br />
34 Armed with Line Fault Alarm - - - User No<br />
Restore - - - -<br />
35 Open/Close (Full Arm) Alarm Open/Close 401 OP User No<br />
Restore Open/Close 401 CL User No<br />
36 Open/Close (Part Arm) Alarm Open/Close 401 OP User No<br />
Restore Open/Close 401 CL User No<br />
37 Auto Open/Close Alarm Open/Close 403 OA 00<br />
Restore Open/Close 403 CA 00<br />
38 Auto Arm Deferred Alarm Open/Close 405 CE User No<br />
Restore Open/Close - - -<br />
39 Open After Alarm (Alarm Abort) Alarm Open/Close 406 OR 00<br />
Restore - - - -<br />
40 Remote Open/Close Alarm Open/Close 407 OP 00<br />
Restore Open/Close 407 CL 00<br />
41 Quick Arm Alarm - - - -<br />
Restore Open/Close 408 CL Keypad No *<br />
42 Recent Closing Alarm Open/Close 459 CR 00<br />
Restore - - - -<br />
43 Reset After Alarm Alarm Restore - - Reset ID ****<br />
Restore - - - -<br />
44 Auxiliary 12V Fuse Fail Alarm Maintenance 300 YP Device ID **<br />
Restore Restore 300 YQ Device ID **<br />