Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Zone Alarm Reporting Codes<br />
The Reporting codes for Contact ID and SIA are fully configurable, however these codes can only be changed using Wintex<br />
downloading software.<br />
The following tables show the default codes for each event on the system:<br />
Default Zone Event Codes<br />
No Zone Type Event Reporting Group Contact ID SIA<br />
00 Entry/Exit 1 Alarm Alarm 134 BA<br />
Alarm Restore Restore 134 BH<br />
Omit Omit/Reinstate 573 BB<br />
Reinstate Omit/Reinstate 573 BU<br />
01 Entry/Exit 2 Alarm Alarm 134 BA<br />
Alarm Restore Restore 134 BH<br />
Omit Omit/Reinstate 573 BB<br />
Reinstate Omit/Reinstate 573 BU<br />
02 Guard Alarm Alarm 132 BA<br />
Alarm Restore Restore 132 BH<br />
Omit Omit/Reinstate 573 BB<br />
Reinstate Omit/Reinstate 573 BU<br />
03 Guard Access Alarm Alarm 132 BA<br />
Alarm Restore Restore 132 BH<br />
Omit Omit/Reinstate 573 BB<br />
Reinstate Omit/Reinstate 573 BU<br />
04 24Hr Audible Alarm Tamper 133 BA<br />
Alarm Restore Restore 133 BH<br />
Omit Omit/Reinstate 572 BB<br />
Reinstate Omit/Reinstate 572 BU<br />
05 24Hr Silent Alarm Tamper 133 BA<br />
Alarm Restore Restore 133 BH<br />
Omit Omit/Reinstate 572 BB<br />
Reinstate Omit/Reinstate 572 BU<br />
06 Audible PA Alarm Priority Alarm 123 PA<br />
Alarm Restore Restore 123 PH<br />
Omit Omit/Reinstate 573 PB<br />
Reinstate Omit/Reinstate 573 PU<br />
07 Silent PA Alarm Priority Alarm 122 HA<br />
Alarm Restore Restore 122 HH<br />
Omit Omit/Reinstate 573 HB<br />
Reinstate Omit/Reinstate 573 HU<br />
08 Fire Alarm Alarm Priority Alarm 110 FA<br />
Alarm Restore Restore 110 FH<br />
Omit Omit/Reinstate 571 FB<br />
Reinstate Omit/Reinstate 571 FU<br />
09 Medical Alarm Priority Alarm 100 MA<br />
Alarm Restore Restore 100 MH<br />
Omit Omit/Reinstate 572 MB<br />
Reinstate Omit/Reinstate 572 MU<br />
10 24Hr Gas Alarm Alarm Tamper 151 GA<br />
Alarm Restore Restore 151 GH<br />
Omit Omit/Reinstate 572 GB<br />
Reinstate Omit/Reinstate 572 GU<br />