<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />

Custom Outputs<br />

Custom outputs are NOT physical outputs they are ‘Software<br />

outputs that can be configured to operate under certain<br />

conditions. Once configured these outputs can then be<br />

assigned to a physical output (see system outputs 22-27 and<br />

32-37, page 59 for details).<br />

Custom Output 1 - 4, Stage A<br />

Will activate when switches 1 or 2 and 3 and 4 are active.<br />

Custom Output 1 - 4, Stage B<br />

Will activate when switches 5 or 6 and 7 and 8 are active.<br />

Custom Output 1 - 4, Stage AB<br />

Will activate when switches 1 or 2 and 3 and 4 are active OR<br />

switches 5 or 6 and 7 and 8 are active.<br />

1<br />

2<br />

5<br />

6<br />

3 4<br />

7 8<br />

Example<br />

Switch 1 is programmed as: Zone 1 Mimic<br />

Switch 2 is programmed as: Zone 2 Mimic<br />

Switch 3 is programmed as: Armed<br />

Switch 4 is programmed as: Never Active (and inverted)<br />

<br />

A<br />

AB<br />

Custom Output 1 Stage A will only activate when<br />

switches 1 OR 2 AND 3 AND 4 are closed.<br />

i.e. if ZONE 1 or ZONE 2 ACTIVATES whilst the system<br />

is ARMED (switch 4 is always closed).<br />

B<br />

X-10 Outputs<br />

X-10 Outputs are outputs that can be configured to operate<br />

devices that are connected to an X-10 controller. These<br />

outputs can be assigned a house and unit number.<br />

To Program an output for X-10, proceed as follows:<br />

Program the output type to ensure correct operation when<br />

the programmed condition occurs i.e. an output programmed<br />

as ‘Entry/Exit’ will activate when the selected area is in the<br />

entry or exit mode and deactivate when the area is no longer<br />

in the entry or exit mode.<br />

Assign any attributes i.e. ‘Pulsed 1’ would cause the output to<br />

be timed for the duration of the ‘Pulse 1’ timer.<br />

Assign a House and Unit number i.e. this is the physical<br />

address of the X-10 Unit and ensures that the correct unit in<br />

the correct area operates when the output condition is met i.e<br />

the correct unit switches on and off during Entry/Exit.<br />

Assign up to 16 Characters of text to each unit to allow easy<br />

identification when the output needs to be manually triggered<br />

directly from the keypad using the command i.e.<br />

‘Entrance Light’.<br />

INS176 63