<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />
Custom Outputs<br />
Custom outputs are NOT physical outputs they are ‘Software<br />
outputs that can be configured to operate under certain<br />
conditions. Once configured these outputs can then be<br />
assigned to a physical output (see system outputs 22-27 and<br />
32-37, page 59 for details).<br />
Custom Output 1 - 4, Stage A<br />
Will activate when switches 1 or 2 and 3 and 4 are active.<br />
Custom Output 1 - 4, Stage B<br />
Will activate when switches 5 or 6 and 7 and 8 are active.<br />
Custom Output 1 - 4, Stage AB<br />
Will activate when switches 1 or 2 and 3 and 4 are active OR<br />
switches 5 or 6 and 7 and 8 are active.<br />
1<br />
2<br />
5<br />
6<br />
3 4<br />
7 8<br />
Example<br />
Switch 1 is programmed as: Zone 1 Mimic<br />
Switch 2 is programmed as: Zone 2 Mimic<br />
Switch 3 is programmed as: Armed<br />
Switch 4 is programmed as: Never Active (and inverted)<br />
<br />
A<br />
AB<br />
Custom Output 1 Stage A will only activate when<br />
switches 1 OR 2 AND 3 AND 4 are closed.<br />
i.e. if ZONE 1 or ZONE 2 ACTIVATES whilst the system<br />
is ARMED (switch 4 is always closed).<br />
B<br />
X-10 Outputs<br />
X-10 Outputs are outputs that can be configured to operate<br />
devices that are connected to an X-10 controller. These<br />
outputs can be assigned a house and unit number.<br />
To Program an output for X-10, proceed as follows:<br />
Program the output type to ensure correct operation when<br />
the programmed condition occurs i.e. an output programmed<br />
as ‘Entry/Exit’ will activate when the selected area is in the<br />
entry or exit mode and deactivate when the area is no longer<br />
in the entry or exit mode.<br />
Assign any attributes i.e. ‘Pulsed 1’ would cause the output to<br />
be timed for the duration of the ‘Pulse 1’ timer.<br />
Assign a House and Unit number i.e. this is the physical<br />
address of the X-10 Unit and ensures that the correct unit in<br />
the correct area operates when the output condition is met i.e<br />
the correct unit switches on and off during Entry/Exit.<br />
Assign up to 16 Characters of text to each unit to allow easy<br />
identification when the output needs to be manually triggered<br />
directly from the keypad using the command i.e.<br />
‘Entrance Light’.<br />
INS176 63