Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />

60 - Armed/Alarm<br />

This output type activates when the selected area is armed<br />

and deactivates when the selected area is disarmed<br />

This output type also pulses when an Intruder alarm occurs in the<br />

selected area, and deactivates when the selected area is<br />

disarmed.<br />

61 - Intruder Alarm<br />

This output type activates when an Intruder alarm occurs, and<br />

deactivates when the Intruder alarm is cancelled.<br />

Tamper alarms will not activate this output<br />

62 - Speaker Mimic<br />

This output type activates whenever the internal speaker<br />

output is on, and deactivates when the speaker output is off.<br />

Output Group - Zone<br />

Any zone can be assigned to this output type. Select a zone<br />

number from 1 to <strong>48</strong> (<strong>Premier</strong> <strong>48</strong>), 1 to <strong>88</strong> (<strong>Premier</strong> <strong>88</strong>) or 1 to<br />

<strong>168</strong> (<strong>Premier</strong> <strong>168</strong>).then select an output type from the following<br />

options:<br />

Mimic<br />

This output type activates when the selected zone is activated<br />

and deactivates when the zone is secure. This output will<br />

work if the zone is armed or disarmed.<br />

MimicArm<br />

This output type activates when the selected zone is activated<br />

and deactivates when the zone is secured. This output will<br />

only work if the zone is armed.<br />

Alarm<br />

This output type activates when the selected zone causes an<br />

alarm and deactivates when the alarm is reset. This output<br />

will only work if the zone is armed.<br />

Tamper<br />

This output type activates when the selected zone causes a<br />

Tamper alarm and deactivates when the tamper is reset. This<br />

output will work if the zone is armed or disarmed.<br />

MimicLat<br />

This output type activates when the selected zone is activated<br />

and deactivates when the next time the zone is activated. This<br />

output will work if the zone is armed or disarmed.<br />

Omitted<br />

This output type activates when the selected zone is omitted<br />

and deactivates when the zone is reinstated.<br />

Output Group - User Code Entered<br />

Any user can be assigned to this output type. Select a user<br />

number from 1 to 25 (<strong>Premier</strong> <strong>48</strong>), 1 to 50 (<strong>Premier</strong> <strong>88</strong>) or 1 to 99<br />

(<strong>Premier</strong> <strong>168</strong>).<br />

This output type activates for 5 seconds when the selected<br />

User code is entered.<br />

Output Group - Control Timer<br />

Select a Control Timer from 1 to 4 (<strong>Premier</strong> <strong>48</strong>) or 1 to 8<br />

(<strong>Premier</strong> <strong>88</strong>/<strong>168</strong>).<br />

These output types activate when the respective control timer<br />

turns on and deactivate when the timer turns off.<br />

Output Group - PC Control<br />

Select a PC Control from 1 to 4 (<strong>Premier</strong> <strong>48</strong>), 1 to 8 (<strong>Premier</strong><br />

<strong>88</strong>/<strong>168</strong>/<strong>640</strong>).<br />

These output types can be activated and deactivated using a<br />

PC running the Wintex UDL software.<br />

Output Group - Door Control<br />

Select a Door Control from 1,1 to 1,4 (<strong>Premier</strong> <strong>48</strong>), 1,1 to 1,8<br />

(<strong>Premier</strong> <strong>88</strong>), 1,1 to 2,8 (<strong>Premier</strong> <strong>168</strong>) or 1,1 to 8,8 (<strong>Premier</strong> <strong>640</strong>).<br />

These output types activate for the duration of the ‘Door<br />

Strike’ timer when a valid User code (assigned to the same<br />

door) is entered and deactivates when the timer expires.<br />

These output types are used in conjunction with the ‘Door<br />

Control’ User option (see page 83 for details).<br />

Output Attributes<br />

Assigning an attribute to an output will alter how the output<br />

works. The following attributes can be assigned to any of the<br />

various types listed.<br />

Select attributes by pressing keys 1 to 8 (a letter on the<br />

display means the attribute is selected, a ‘Dot’ on the display<br />

means the attribute is not selected).<br />

U - User Test<br />

The output will activate when a user performs a User test (see<br />

page 87 for details).<br />

I - Inverted<br />

The output is inverted (an output that applies 0V when active<br />

will become an output that applies 12V when active).<br />

L - Latching<br />

When activated, the output will remain on until a valid User<br />

code is entered.<br />

1 - Use Pulse Period 1<br />

When activated, the output will remain on for the duration of<br />

the ‘Pulse Period 1’ timer (see page 44 for details).<br />

2 - Use Pulse Period 2<br />

When activated, the output will remain on for the duration of<br />

the ‘Pulse Period 2’ timer (see page 44 for details).<br />

3 - Use Pulse Period 3<br />

When activated, the output will remain on for the duration of<br />

the ‘Pulse Period 3’ timer (see page 44 for details).<br />

C - Only Active With Custom Output 1 Stage A<br />

The output will only operate whilst ‘Custom Output Stage A’<br />

is ‘On’ (see page ‘Custom Outputs’ for details).<br />

R - Random<br />

The output will activate randomly. A minimum and maximum<br />

‘On’ time can also be programmed (see page 44 for details).<br />

62 INS176