Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
60 - Armed/Alarm<br />
This output type activates when the selected area is armed<br />
and deactivates when the selected area is disarmed<br />
This output type also pulses when an Intruder alarm occurs in the<br />
selected area, and deactivates when the selected area is<br />
disarmed.<br />
61 - Intruder Alarm<br />
This output type activates when an Intruder alarm occurs, and<br />
deactivates when the Intruder alarm is cancelled.<br />
Tamper alarms will not activate this output<br />
62 - Speaker Mimic<br />
This output type activates whenever the internal speaker<br />
output is on, and deactivates when the speaker output is off.<br />
Output Group - Zone<br />
Any zone can be assigned to this output type. Select a zone<br />
number from 1 to <strong>48</strong> (<strong>Premier</strong> <strong>48</strong>), 1 to <strong>88</strong> (<strong>Premier</strong> <strong>88</strong>) or 1 to<br />
<strong>168</strong> (<strong>Premier</strong> <strong>168</strong>).then select an output type from the following<br />
options:<br />
Mimic<br />
This output type activates when the selected zone is activated<br />
and deactivates when the zone is secure. This output will<br />
work if the zone is armed or disarmed.<br />
MimicArm<br />
This output type activates when the selected zone is activated<br />
and deactivates when the zone is secured. This output will<br />
only work if the zone is armed.<br />
Alarm<br />
This output type activates when the selected zone causes an<br />
alarm and deactivates when the alarm is reset. This output<br />
will only work if the zone is armed.<br />
Tamper<br />
This output type activates when the selected zone causes a<br />
Tamper alarm and deactivates when the tamper is reset. This<br />
output will work if the zone is armed or disarmed.<br />
MimicLat<br />
This output type activates when the selected zone is activated<br />
and deactivates when the next time the zone is activated. This<br />
output will work if the zone is armed or disarmed.<br />
Omitted<br />
This output type activates when the selected zone is omitted<br />
and deactivates when the zone is reinstated.<br />
Output Group - User Code Entered<br />
Any user can be assigned to this output type. Select a user<br />
number from 1 to 25 (<strong>Premier</strong> <strong>48</strong>), 1 to 50 (<strong>Premier</strong> <strong>88</strong>) or 1 to 99<br />
(<strong>Premier</strong> <strong>168</strong>).<br />
This output type activates for 5 seconds when the selected<br />
User code is entered.<br />
Output Group - Control Timer<br />
Select a Control Timer from 1 to 4 (<strong>Premier</strong> <strong>48</strong>) or 1 to 8<br />
(<strong>Premier</strong> <strong>88</strong>/<strong>168</strong>).<br />
These output types activate when the respective control timer<br />
turns on and deactivate when the timer turns off.<br />
Output Group - PC Control<br />
Select a PC Control from 1 to 4 (<strong>Premier</strong> <strong>48</strong>), 1 to 8 (<strong>Premier</strong><br />
<strong>88</strong>/<strong>168</strong>/<strong>640</strong>).<br />
These output types can be activated and deactivated using a<br />
PC running the Wintex UDL software.<br />
Output Group - Door Control<br />
Select a Door Control from 1,1 to 1,4 (<strong>Premier</strong> <strong>48</strong>), 1,1 to 1,8<br />
(<strong>Premier</strong> <strong>88</strong>), 1,1 to 2,8 (<strong>Premier</strong> <strong>168</strong>) or 1,1 to 8,8 (<strong>Premier</strong> <strong>640</strong>).<br />
These output types activate for the duration of the ‘Door<br />
Strike’ timer when a valid User code (assigned to the same<br />
door) is entered and deactivates when the timer expires.<br />
These output types are used in conjunction with the ‘Door<br />
Control’ User option (see page 83 for details).<br />
Output Attributes<br />
Assigning an attribute to an output will alter how the output<br />
works. The following attributes can be assigned to any of the<br />
various types listed.<br />
Select attributes by pressing keys 1 to 8 (a letter on the<br />
display means the attribute is selected, a ‘Dot’ on the display<br />
means the attribute is not selected).<br />
U - User Test<br />
The output will activate when a user performs a User test (see<br />
page 87 for details).<br />
I - Inverted<br />
The output is inverted (an output that applies 0V when active<br />
will become an output that applies 12V when active).<br />
L - Latching<br />
When activated, the output will remain on until a valid User<br />
code is entered.<br />
1 - Use Pulse Period 1<br />
When activated, the output will remain on for the duration of<br />
the ‘Pulse Period 1’ timer (see page 44 for details).<br />
2 - Use Pulse Period 2<br />
When activated, the output will remain on for the duration of<br />
the ‘Pulse Period 2’ timer (see page 44 for details).<br />
3 - Use Pulse Period 3<br />
When activated, the output will remain on for the duration of<br />
the ‘Pulse Period 3’ timer (see page 44 for details).<br />
C - Only Active With Custom Output 1 Stage A<br />
The output will only operate whilst ‘Custom Output Stage A’<br />
is ‘On’ (see page ‘Custom Outputs’ for details).<br />
R - Random<br />
The output will activate randomly. A minimum and maximum<br />
‘On’ time can also be programmed (see page 44 for details).<br />
62 INS176