<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />

30 - Strobe<br />

This output type activates when an External alarm (or Arm Fail)<br />

occurs in the selected area, and deactivates when area is<br />

disarmed (or a valid User code is entered).<br />

31 - Detector Latch<br />

This output type activates for 5 seconds when the selected<br />

area is in the exit mode then activates again when the area<br />

arms and deactivates when an Intruder alarm occurs or the<br />

selected area is disarmed.<br />

32 - Detector Reset<br />

This output type is normally active, and deactivates for 5<br />

seconds when the selected area is in the exit mode.<br />

33 - Walk Test Active<br />

This output type activates when the ‘Walk Test’ procedure is<br />

selected, and deactivates when the ‘Walk Test’ procedure is<br />

cancelled.<br />

34 - Zones Omitted<br />

This output type activates when a zone in the selected area<br />

with the ‘Omit’ attribute, is omitted by the user, and<br />

deactivates when the zone is reinstated.<br />

35 - 24Hr Zones Omit<br />

This output type activates when a zone programmed as ‘24Hr<br />

Audible’ or ‘24Hr Silent’ (with the ‘Omit’ attribute) is omitted by<br />

the user, and deactivates when the zone is reinstated.<br />

36 - Reset Required<br />

This output type activates when the selected area requires a<br />

reset following an alarm, and deactivates when the alarm is<br />

reset.<br />

37 - Door Strike<br />

This output type activates for the 4 seconds when a User<br />

code with the ‘Door Strike’ attribute is entered for the selected<br />

area.<br />

38 - Chime Mimic<br />

This output type activates for 2 seconds when a zone in the<br />

selected area with the ‘Chime’ attribute is activated.<br />

39 - Chime Enabled<br />

This output type activates when ‘Chime’ is enabled for the<br />

selected area, and deactivates when ‘Chime’ is disabled for<br />

the selected area.<br />

40 - DK First Knock<br />

This output type activates when a zone in the selected area<br />

with the ‘Double Knock’ attribute is activated for the first time,<br />

and deactivates when the zone causes an alarm or the<br />

‘Double Knock Delay’ timer expires.<br />

41 - BP First Knock<br />

This output type activates when a zone in the selected area<br />

with the ‘Beam Pair’ attribute is activated for the first time and<br />

deactivates when another zone with the ‘Beam Pair’ attribute,<br />

causes an alarm or the ‘Beam Pair Time’ expires.<br />

42 - On Test<br />

This output type activates when a zone in the selected area<br />

with the ‘Test’ attribute is placed on test and deactivates when<br />

the ‘Soak Test Time’ expires.<br />

43 - Test Fail<br />

This output type activates when a zone in the selected area with<br />

the ‘Test’ attribute is placed on test (and fails) and deactivates<br />

when an Engineer code is entered or the ‘Soak Test Time’ expires.<br />

44 - Internal Alarm<br />

This output type activates when an Internal alarm occurs in the<br />

selected area, and deactivates when the alarm is cancelled.<br />

45 - Auto Arming<br />

This output type activates when the selected area ‘Auto<br />

Arms’, and deactivates when the selected area is disarmed.<br />

46 - Time Arming<br />

This output type activates for 5 minutes prior to the selected<br />

area being armed using the ‘Control Timers’.<br />

47 - 1st Code Entered<br />

This output type activates for 30 seconds when a User code<br />

with the ‘Dual Code’ attribute is entered for the selected area.<br />

<strong>48</strong> - 2nd Code Entered<br />

This output type activates for 30 seconds when two User<br />

codes with the ‘Dual Code’ attribute are entered for the<br />

selected area.<br />

49 - Area Secured<br />

This output type activates whenever a ‘Security Key’ zone<br />

type is used to lock keypads out and deactivates when the<br />

keypads are unlocked again.<br />

50 - Part Armed 1<br />

This output type activates when a Part Arm 1 is selected for<br />

the selected area and deactivates when part arm 1 is<br />

disarmed.<br />

51 - Part Armed 2<br />

This output type activates when a Part Arm 2 is selected for<br />

the selected area and deactivates when part arm 2 is<br />

disarmed.<br />

52 - Part Armed 3<br />

This output type activates when a Part Arm 3 is selected for<br />

the selected area and deactivates when part arm 3 is<br />

disarmed.<br />

53 - Custom Alarm<br />

This output type activates when any ‘Custom’ zone type<br />

causes an alarm in the selected area and deactivates when a<br />

valid user code is entered.<br />

54 - Zone Warning<br />

This output type activates when ‘Custom’ zone type in the<br />

selected area with the ‘Warning Req’ attribute (see page 36 for<br />

details) is activated for the duration of the ‘Warning Delay’<br />

timer (see page 45 for details) and deactivates when the zone<br />

activity is cleared.<br />

55 - Arm Fail Warning<br />

This output type activates when the selected area fails to arm<br />

after a period of time (controlled by the area exit time) when<br />

using ‘Entry/Exit’ or ‘Exit Term.’ arming and deactivates when<br />

the area arms.<br />

56 - Forced Entry<br />

This output type activates for the duration of the ‘Forced<br />

Entry’ timer (see page 45 for details) when any ‘Guard’ or<br />

‘Custom’ zone with the ‘Guard’ attribute is activated (see<br />

page 35 for details),.<br />

57 - Zones Locked Out<br />

This output type activates when any zone is locked out<br />

following an Intruder Alarm activation and deactivates when<br />

all zones are clear and reinstated.<br />

58 - All Areas Armed<br />

This output type activates when all of the selected areas are<br />

armed and deactivates when any one of those areas is<br />

disarmed.<br />

59 - Time Arm Disabled<br />

This output type activates when the timed arming procedure<br />

is disabled (see page 36 for details) and deactivates when<br />

timed arming is reinstated.<br />

INS176 61