Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Output Group - Area<br />
Any number of areas can be assigned to each output type.<br />
Select an output type from the following options:<br />
00 - Alarm<br />
This output type activates when an Intruder alarm occurs in the<br />
selected area, and deactivates when the Intruder alarm is reset.<br />
01 - Guard Alarm<br />
This output type activates when a zone programmed as<br />
‘Guard’ causes an Intruder alarm in the selected area and<br />
deactivates when the alarm is reset.<br />
02 - Guard Access Alarm<br />
This output type activates when a zone programmed as<br />
‘Guard Access’ causes an Intruder alarm in the selected area<br />
and deactivates when the alarm is reset.<br />
03 - Entry Alarm<br />
This output type activates when a zone programmed as<br />
‘Entry/Exit 1 or 2’ causes an Intruder alarm in the selected<br />
area and deactivates when the alarm is reset.<br />
04 - Confirmed Alarm<br />
If the area is already in alarm, this output type activates when a<br />
different zone (not on the entry route) is activated and<br />
deactivates at the end of the ‘Confirmation’ time, when a code is<br />
entered within the ‘Abort’ time or when the alarm is reset.<br />
05 - 24Hr Audible<br />
This output type activates when a zone programmed as ‘24Hr<br />
Audible’ causes an Internal alarm or Intruder alarm in the<br />
selected area and deactivates when the alarm is reset.<br />
06 - 24Hr Silent<br />
This output type activates when a zone programmed as ‘24Hr<br />
Silent’ causes a silent alarm or Intruder alarm in the selected<br />
area and deactivates when the alarm is reset.<br />
07 - 24Hr Gas<br />
This output type activates when a zone programmed as ‘24Hr<br />
Gas’ causes a Silent alarm or Intruder alarm in the selected<br />
area and deactivates when the alarm is reset.<br />
08 - PA Alarm<br />
This output type activates when any type of ‘PA alarm’ i.e. PA<br />
audible, PA silent or Duress causes a PA alarm in the<br />
selected area and deactivates when the alarm is reset.<br />
09 - PA Silent<br />
This output type activates when a zone programmed as ‘PA<br />
Silent’ or a keypad PA (1 & 3) causes a silent PA alarm in the<br />
selected area and deactivates when the alarm is reset.<br />
10 - Duress<br />
This output type activates when a User code with the ‘Duress’<br />
attribute causes a silent PA alarm in the selected area and<br />
deactivates when the alarm is reset.<br />
11 - Fire Alarm<br />
This output type activates when a zone programmed as ‘Fire’<br />
or a keypad Fire (4 & 6) causes a Fire alarm in the selected<br />
area and deactivates when the alarm is reset.<br />
12 - Medical<br />
This output type activates when a zone programmed as ‘Medical’<br />
or a keypad Medical (7 & 9) causes a Medical alarm in the<br />
selected area and deactivates when the alarm is reset.<br />
13 - Auxiliary Alarm<br />
This output type activates when a zone programmed as<br />
‘Auxiliary’ causes a Silent alarm in the selected area and<br />
deactivates when the alarm is reset.<br />
14 - Tamper Alarm<br />
This output type activates when any type of Tamper alarm<br />
occurs in the selected area and deactivates when the alarm is<br />
reset.<br />
15 - Alarm Abort<br />
If the selected area is in alarm, this output type activates<br />
when a User code is entered to cancel the alarm in the<br />
selected area and deactivates after 10 seconds.<br />
16 - Ready<br />
This output type activates when all zones in the selected area<br />
are secure and deactivates when any zone in the selected<br />
area is activated.<br />
17 - Entry Mode<br />
This output type activates when the selected area is in the<br />
entry mode and deactivates when the area is not in the entry<br />
mode.<br />
18 - 2nd Entry Mode<br />
This output type activates when the 2nd entry timer for the<br />
selected area starts and deactivates when the 2nd entry timer<br />
expires.<br />
19 - Exit Mode<br />
This output type activates when the selected area is in the exit<br />
mode and deactivates when the area is not in the exit mode.<br />
20 - Entry/Exit Mode<br />
This output type activates when the selected area is in the<br />
entry or exit mode and deactivates when the area is no longer<br />
in the entry or exit mode.<br />
21 - Armed<br />
This output type activates when the selected area is armed<br />
and deactivates when the selected area is disarmed.<br />
22 - Full Armed<br />
This output type activates when the selected area is fully armed<br />
and deactivates when the selected area is disarmed.<br />
23 - Part Armed<br />
This output type activates when the selected area is part armed<br />
and deactivates when the selected area is disarmed.<br />
24 - Part Arming<br />
This output type activates when the selected area is part<br />
arming and deactivates when the selected area arms.<br />
25 - Force Arm<br />
This output type activates when the selected area has at least<br />
one zone with the ‘Force Omit’ attribute assigned to it, and<br />
deactivates when the area has no zones with the ‘Auto Omit’<br />
attribute assigned to it.<br />
26 - Force Arming<br />
This output type activates when the selected area is forced to<br />
arm with zones active, and deactivates when the zone is<br />
reinstated.<br />
27 - Arm Failed<br />
This output type activates when the selected area fails to arm<br />
because a zone is in fault, and deactivates when a valid User<br />
code is entered.<br />
28 - Bell SAB<br />
This output type activates when an External alarm occurs in the<br />
selected area, and deactivates when area is disarmed or the<br />
‘Bell Duration’ timer expires.<br />
29 - Bell SCB<br />
This output type deactivates when an External alarm occurs in<br />
the selected area, and activates when area is disarmed or the<br />
‘Bell Duration’ timer expires.<br />
60 INS176