Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />

System Options<br />

<br />

<br />

Yes<br />

<br />

<br />

2 abc<br />

<br />

<br />

Yes<br />

<br />

<br />

Yes<br />

<br />

<br />

No<br />

<br />

<br />

7 pqrs<br />

<br />

<br />

Yes<br />

Use the YES key to move<br />

to the next option or use<br />

the SCROLL key to search<br />

Press NO to edit<br />

the volume level<br />

Enter a value or use the<br />

SCROLL key to increase<br />

or decrease the value<br />

e.g. 8 = Full Volume<br />

These options control various system functions.<br />

1 - Advisory Volume<br />

Controls the volume of advisory tones (entry/exit etc.) from<br />

loudspeakers connected to the control panel (Alarm tones are<br />

always full volume). 1 = min, 8 = max.<br />

2 - Chime Volume<br />

Controls the volume level of Chime tones from ALL<br />

loudspeakers. 1 = min, 8 = max.<br />

3 - No. Of Re-Arms<br />

Controls the number of times that a zone will re-arm. Once the rearm<br />

limit has been reached, the zone is ‘Locked Out’ and will not<br />

cause any further Intruder alarms.<br />

4 - Anti-code Resets<br />

Limits how many times a user can perform an Anti-code reset.<br />

Once this limit is been reached, the system can only be reset<br />

using an Engineer code. This counter is reset every month or<br />

whenever an Engineers code is entered.<br />

5 - Multiple Knocks<br />

Controls how many times, a zone with the ‘Double Knock’<br />

attribute, must be activated, before an alarm occurs. The<br />

multiple knock count can be applied to zones on an area<br />

basis, see page 42 for details.<br />

6 - Clock Adjustment<br />

Adjusts the accuracy of the clock by subtracting or adding<br />

time in seconds at midnight every night. 0 = -50, 50 = 0 (no<br />

correction), 100 = +50.<br />

7 - Quick Count<br />

Set the number of 10milli Second pulses that are required<br />

within 30 Seconds in order for a zone with the ‘Quick<br />

Response’ attribute to activate.<br />

8 - Modem Level<br />

When using a Com2400 this option allows adjustment to the<br />

attenuation of the modem.<br />

Modem Level 2 1 0 7 6 5 4 3<br />

Attenuation (dB) +4 +2 0 -2 -4 -6 -8 -10<br />

Monitor Hardware<br />

<br />

<br />

<strong>48</strong> INS176<br />

Yes<br />

<br />

<br />

3 def<br />

<br />

<br />

Yes<br />

<br />

<br />

No<br />

<br />

<br />

<br />

<br />

No<br />

<br />

<br />

Yes<br />

Press NO to edit<br />

the options<br />

Use keys 1 - 8 to select<br />

an attribute or use the<br />

SCROLL key to search<br />

Press NO to<br />

select/deselect<br />

the option<br />

The control panel monitors many inputs for fault conditions<br />

i.e. the panel lid tamper, bell tamper, aux fuse etc.<br />

Each one of these options can be disabled to overcome<br />

problems related to the devices being monitored.<br />

P - Phone Line Fault<br />

The telephone line is monitored for faults.<br />

A - AC Power Failure<br />

The AC Mains is monitored for faults.<br />

F - Aux Fuse Blown<br />

The Auxiliary Fuse/PTC is monitored for faults.<br />

B - Bell Tamper<br />

The external sounder tamper loop is monitored for faults.<br />

A - Aux Tamper<br />

The auxiliary tamper loop is monitored for faults.<br />

L - Panel Lid Tamper<br />

The control panel lid tamper is monitored for faults.<br />

B - Battery Faults<br />

The dynamic battery test is enabled.