Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
System Options<br />
<br />
<br />
Yes<br />
<br />
<br />
2 abc<br />
<br />
<br />
Yes<br />
<br />
<br />
Yes<br />
<br />
<br />
No<br />
<br />
<br />
7 pqrs<br />
<br />
<br />
Yes<br />
Use the YES key to move<br />
to the next option or use<br />
the SCROLL key to search<br />
Press NO to edit<br />
the volume level<br />
Enter a value or use the<br />
SCROLL key to increase<br />
or decrease the value<br />
e.g. 8 = Full Volume<br />
These options control various system functions.<br />
1 - Advisory Volume<br />
Controls the volume of advisory tones (entry/exit etc.) from<br />
loudspeakers connected to the control panel (Alarm tones are<br />
always full volume). 1 = min, 8 = max.<br />
2 - Chime Volume<br />
Controls the volume level of Chime tones from ALL<br />
loudspeakers. 1 = min, 8 = max.<br />
3 - No. Of Re-Arms<br />
Controls the number of times that a zone will re-arm. Once the rearm<br />
limit has been reached, the zone is ‘Locked Out’ and will not<br />
cause any further Intruder alarms.<br />
4 - Anti-code Resets<br />
Limits how many times a user can perform an Anti-code reset.<br />
Once this limit is been reached, the system can only be reset<br />
using an Engineer code. This counter is reset every month or<br />
whenever an Engineers code is entered.<br />
5 - Multiple Knocks<br />
Controls how many times, a zone with the ‘Double Knock’<br />
attribute, must be activated, before an alarm occurs. The<br />
multiple knock count can be applied to zones on an area<br />
basis, see page 42 for details.<br />
6 - Clock Adjustment<br />
Adjusts the accuracy of the clock by subtracting or adding<br />
time in seconds at midnight every night. 0 = -50, 50 = 0 (no<br />
correction), 100 = +50.<br />
7 - Quick Count<br />
Set the number of 10milli Second pulses that are required<br />
within 30 Seconds in order for a zone with the ‘Quick<br />
Response’ attribute to activate.<br />
8 - Modem Level<br />
When using a Com2400 this option allows adjustment to the<br />
attenuation of the modem.<br />
Modem Level 2 1 0 7 6 5 4 3<br />
Attenuation (dB) +4 +2 0 -2 -4 -6 -8 -10<br />
Monitor Hardware<br />
<br />
<br />
<strong>48</strong> INS176<br />
Yes<br />
<br />
<br />
3 def<br />
<br />
<br />
Yes<br />
<br />
<br />
No<br />
<br />
<br />
<br />
<br />
No<br />
<br />
<br />
Yes<br />
Press NO to edit<br />
the options<br />
Use keys 1 - 8 to select<br />
an attribute or use the<br />
SCROLL key to search<br />
Press NO to<br />
select/deselect<br />
the option<br />
The control panel monitors many inputs for fault conditions<br />
i.e. the panel lid tamper, bell tamper, aux fuse etc.<br />
Each one of these options can be disabled to overcome<br />
problems related to the devices being monitored.<br />
P - Phone Line Fault<br />
The telephone line is monitored for faults.<br />
A - AC Power Failure<br />
The AC Mains is monitored for faults.<br />
F - Aux Fuse Blown<br />
The Auxiliary Fuse/PTC is monitored for faults.<br />
B - Bell Tamper<br />
The external sounder tamper loop is monitored for faults.<br />
A - Aux Tamper<br />
The auxiliary tamper loop is monitored for faults.<br />
L - Panel Lid Tamper<br />
The control panel lid tamper is monitored for faults.<br />
B - Battery Faults<br />
The dynamic battery test is enabled.