<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />
26 - Keypad PA Delay<br />
When keypad ‘option 6’ is programmed as ‘PA Delayed’ (see<br />
page 54 for details), and a keypad PA alarm (1 & 3) is<br />
activated, this timer starts. If a User code is entered before<br />
this timer expires, no PA alarm will occur. However, if a User<br />
code is not entered before this timer expires, a PA alarm will<br />
occur.<br />
27 - Confirmation Dly<br />
When an Intruder alarm occurs, this timer starts. If a second<br />
(different) zone is activated within this time window, the<br />
‘Confirmed’ output will activate. When this timer<br />
expires, the ‘Confirmed’ output will no longer activate.<br />
28 - Warning Delay<br />
When a Custom zone with the ‘Warning Req’ attribute (see<br />
page 36 for details) activates, this timer is started. If the zone<br />
is still active when this timer expires a warning tone or alarm<br />
will occur and the Warning Output (see page 61 for details)<br />
will activate.<br />
29 - Keypad Lock Time<br />
If keypad tampers have been programmed to lockout the<br />
keypad (see page 46 for details), the keypad will lock out for<br />
the duration of this timer.<br />
30 - Eng. log off Dly<br />
This timer starts when an Engineers code is entered. When the<br />
timer expires the engineer is automatically logged out of<br />
engineer’s mode. This timer is suspended if there are tamper<br />
faults on the system allowing the engineer to remain in<br />
engineer’s mode indefinitely whilst on site.<br />
31 - Fire Bell Delay<br />
This timer starts when a fire alarm is generated in a particular<br />
area. When the timer expires sounders are activated in ALL<br />
areas.<br />
32 - Forced Entry Dly<br />
When a zone with the ‘Guard’ attribute (see page 35 for<br />
details) activates, this timer is started. For the duration of this<br />
timer, any ‘Entry/Exit 1 or 2’ zone with the ‘Entry/Exit 2’<br />
attribute (see page 35 for details) will become a ‘Guard’ zone.<br />
When this timer expires, the ‘Entry/Exit 1 or 2’ zone will revert<br />
back to its normal mode of operation.<br />
33 - Supervision Time<br />
This timer controls the frequency at which the RadioPLUS<br />
detectors are required to report in to the control panel.<br />
34 - Poll IP Every<br />
This timer controls the frequency that the ComIP Polls the<br />
ARC.<br />
System Config.<br />
<br />
<br />
INS176 45<br />
Yes<br />
<br />
<br />
1<br />
<br />
<br />
Yes<br />
<br />
<br />
??<br />
<br />
<br />
No<br />
<br />
<br />
Yes<br />
Enter a configuration<br />
number or use the<br />
SCROLL key to search<br />
e.g. 09 = NVM Unlocked<br />
Press NO to change<br />
the config. option<br />
These options control how various system functions work.<br />
00 - No Bell Arm Fail<br />
If an area fails to arm, an Internal alarm will occur and the<br />
‘Strobe’ output will activate.<br />
Bell on Arm Fail<br />
If an area fails to arm, an Internal alarm will occur and the<br />
‘Bell’ output will activate for 10 seconds.<br />
<br />
The ‘Strobe’ output will also activate for 5 seconds to<br />
indicate that the system has armed/disarmed.<br />
01 - Bell is an SAB<br />
The ‘Bell’ output on the control panel applies 0V when active.<br />
Bell is an SCB<br />
The ‘Bell' output on the control panel removes 0V when active.<br />
02 - Clock is 24Hr<br />
The system time is displayed in the 24-Hour format.<br />
Clock is 12Hr (Default)<br />
The system time is displayed in the 12-Hour format.<br />
03 - Auto BST/GMT<br />
The system clock will adjust itself at the beginning and the<br />
end of the summer (the clock will automatically gain 1Hr on<br />
the last Sunday in March and lose 1Hr on the last Sunday in<br />
October.<br />
<strong>Manual</strong> BST/GMT<br />
The system clock will not adjust itself at the beginning and<br />
the end of the summer (the clock will have to be adjusted<br />
manually).<br />
04 - View Armed Areas<br />
When the system is part armed, the areas that are armed are<br />
displayed and alarm information is displayed before a valid<br />
User code is entered.<br />
Hide Armed Areas<br />
When the system is part armed, the areas that are armed are<br />
not displayed and alarm information is only displayed after a<br />
valid User code has been entered.