Programming the Control Panel <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Area Options<br />
<br />
<br />
Yes<br />
<br />
<br />
5 jkl<br />
<br />
<br />
Yes<br />
<br />
<br />
<br />
<br />
No<br />
<br />
<br />
4 ghi<br />
<br />
<br />
Yes<br />
Use the SCROLL<br />
key to select an<br />
area option<br />
Press NO to change<br />
the area option<br />
Use keys 1 - 8<br />
to select an area<br />
e.g. 4 = D<br />
These options control how various features affect each area.<br />
Any number of areas can be assigned to each option.<br />
1 - Auto Part Arm<br />
Areas assigned to ‘Auto Part Arm’ will fully arm if an<br />
‘Entry/Exit’ zone is activated during the exit mode and will<br />
‘Part Arm 1’ if an ‘Entry/Exit’ zone is not activated during the<br />
exit mode.<br />
Areas not assigned to ‘Auto Part’ will always fully arm.<br />
2 - Part Arm Instant<br />
Areas assigned to ‘Part Arm Instant’ will arm instantly when<br />
part arming.<br />
Areas not assigned to ‘Part Arm Instant’ will use the area exit<br />
timer when part arming.<br />
3 - Part Arm Silent<br />
Areas assigned to ‘Part Arm Silent’ will never generate Exit<br />
tones when part arming.<br />
Areas not assigned to ‘Part Arm Silent’ will always generate<br />
Exit tones when part arming.<br />
4 - Remote Arm<br />
Areas assigned to ‘Remote Arm’ can be armed remotely<br />
using the Wintex UDL software and a PC.<br />
Areas not assigned cannot be armed remotely.<br />
5 - Remote Disarm<br />
Areas assigned to ‘Remote Disarm’ can be disarmed<br />
remotely using the Wintex UDL software and a PC.<br />
Areas not assigned to ‘Remote Arming’ cannot be disarmed<br />
remotely.<br />
6 - Panel Tamper<br />
Areas assigned to ‘Panel Tamper’ will cause a Tamper alarm<br />
when the control panel cover is removed.<br />
Areas not assigned to ‘Panel Tamper’ will never cause a<br />
Tamper alarm when the control panel cover is removed.<br />
7 - Bell Tamper<br />
Areas assigned to ‘Bell Tamper’ will cause a Tamper alarm<br />
when the Bell tamper loop is broken.<br />
Areas not assigned to ‘Bell Tamper’ will never cause a<br />
Tamper alarm when the bell tamper loop is broken.<br />
8 - Auxiliary Tamper<br />
Areas assigned to ‘Auxiliary Tamper’ will cause a Tamper<br />
alarm when the Auxiliary tamper loop is broken.<br />
Areas not assigned to ‘Auxiliary Tamper’ will never cause a<br />
Tamper alarm when the auxiliary tamper loop is broken.<br />
9 - Panel Speaker<br />
Areas assigned to ‘Panel Speaker’ will cause the control<br />
panel speaker to activate when those areas are in alarm,<br />
entry and exit etc.<br />
Areas not assigned to ‘Panel Speaker’ will never cause the<br />
control panel speaker to activate when those areas are in<br />
alarm, entry and exit etc.<br />
10 - Bell & Strobe op<br />
Areas assigned to ‘Bell & Strobe op’ will cause the<br />
‘Bell/Strobe’ output on the control panel to activate when an<br />
alarm occurs in those areas.<br />
Areas not assigned to ‘Bell & Strobe op’ will never cause the<br />
‘Bell/Strobe’ output on the control panel to activate when an<br />
alarm occurs in those areas.<br />
11 - Alarms Eng Reset<br />
Each area can be programmed for Engineer or User reset<br />
following an Intruder alarm. Areas Assigned to ‘Alarms Eng<br />
Reset’ will respond as follows:<br />
• The assigned areas can only be reset using an Engineer<br />
code<br />
If ‘Anti-code Reset’ is enabled (option 11) the assigned<br />
areas can also be reset using the Anti-code<br />
Areas not assigned to ‘Alarms Eng Reset’ can be reset with<br />
any User code that is valid for those areas.<br />
12 - Confirmed Reset<br />
Each area can be programmed for Engineer or User reset<br />
following a Confirmed alarm. Areas Assigned to ‘Confirmed<br />
Reset’ will respond as follows:<br />
• The assigned areas can only be reset using an Engineer<br />
code<br />
If ‘Anti-code Reset’ is enabled (option 11) the assigned<br />
areas can also be reset using the Anti-code<br />
Areas not assigned to ‘Confirmed Reset’ can only be reset<br />
with any User code that is valid for those areas providing that<br />
‘Alarms Eng Reset’ (option 11) is also programmed for user<br />
reset.<br />
13 - Tamper Eng Reset<br />
Each area can be programmed for Engineer or User reset<br />
following a Tamper alarm (when the area is unarmed). Areas<br />
assigned to ‘Tamper Eng Reset’ will respond as follows:<br />
• The assigned areas can only be reset using an Engineer<br />
code<br />
• If ‘Anti-code Reset’ is enabled (option 11) the assigned<br />
areas can also be reset using the Anti-code<br />
Areas not assigned to ‘Tamper Eng Reset’ can be reset with<br />
any User code that is valid for those areas.<br />