<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />

Area Suite Text<br />

<br />

<br />

Yes<br />

<br />

<br />

3 def<br />

<br />

<br />

Yes<br />

<br />

<br />

4 ghi<br />

<br />

<br />

No<br />

<br />

<br />

????<br />

<br />

<br />

Yes<br />

Use keys 1 - 8 to select<br />

an Area Arm Suite or use the<br />

SCROLL key to search e.g. 4<br />

Press NO to edit the<br />

Area Arm Suite text<br />

Use keys 0 - 9 to program<br />

text the same way that a<br />

mobile phone works<br />

Text may be assigned to the Area Arm Suites to allow the user<br />

to select the suites by description instead of number. Up to 16<br />

characters of text can be programmed for each suite.<br />

Example<br />

Text descriptions for the Area Arm Suites could be useful<br />

where more than one suite has been defined. The user<br />

wishes to arm areas A and B at night but is not too sure<br />

which suite to select.<br />

• Areas ‘A and B’ would be assigned to ‘Area Arm Suite 1’<br />

(see page 38 for details)<br />

• When the user wants to arm the system at night, ‘Area<br />

Arm Suite 1’ would be selected<br />

• Text will be displayed to confirm that the selected suite is<br />

correct i.e. ‘Bedtime Setting’<br />

• Areas A and B are automatically selected for armed<br />

Text is programmed in a similar way to mobile phones. Select<br />

characters by pressing the corresponding key the<br />

appropriate number of times (to select a character on the<br />

same key, press to move the cursor along).<br />

Suite Arm Modes<br />

<br />

<br />

INS176 39<br />

Yes<br />

<br />

<br />

4 ghi<br />

<br />

<br />

Yes<br />

<br />

<br />

<br />

<br />

<br />

<br />

1<br />

Yes<br />

Use the SCROLL key<br />

to select a suite<br />

Use keys 1 - 5 to select<br />

an arming mode<br />

e.g. 1 = Entry/Exit<br />

The way that an Area Arm Suite arms when selected, can be<br />

configured for any of the following options:<br />

1 - Entry/Exit<br />

The suite will arm after the ‘Entry/Exit’ door has been closed<br />

and the ‘Exit Settle’ timer has expired.<br />

2 - Exit Term.<br />

The suite will arm after the ‘Entry/Exit’ door has been closed,<br />

the ‘Exit Terminator’ button has been pressed and the ‘Exit<br />

Settle’ timer has expired.<br />

3 - Timed Exit (Default for All Areas)<br />

The suite will arm after the programmed ‘Exit Time’ has<br />

expired.<br />

<br />

If an ‘Exit Terminator’ zone is activated at any point<br />

during the exit mode, any remaining exit time is<br />

cancelled and the area will arm immediately.<br />

4 - Instant<br />

The suite will arm instantly.<br />

5 - Deferred<br />

The suite will arm after the programmed ‘Exit Time’ has<br />

expired. However, if any zones not on the exit route are<br />

activated during the exit mode, the ‘Exit Time’ is restarted.