<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />
5.2 Area Programming<br />
Timers<br />
<br />
<br />
Yes<br />
<br />
<br />
Yes<br />
<br />
<br />
<br />
<br />
Reset<br />
Yes<br />
<br />
<br />
???<br />
<br />
<br />
Yes<br />
Use the SCROLL key to<br />
select an area<br />
Press YES to move to<br />
the required timer group<br />
or press RESET to move<br />
backwards e.g. YES<br />
Enter a new timer value<br />
e.g. 025 = 25 Seconds<br />
These groups of ‘Area’ timers control timing and delay<br />
functions for areas 1 – 4 (<strong>Premier</strong> <strong>48</strong>), 1 - 8 (<strong>Premier</strong> <strong>88</strong>) and 1<br />
- 16 (<strong>Premier</strong> <strong>168</strong> and <strong>640</strong>). Each timer can be programmed<br />
for any value between 000 and 999.<br />
1 - Exit Delay- for Areas A to D (A to H) (A to P)<br />
When the area exit mode is programmed as ‘Timed’ this timer<br />
controls the delay between the user initiating the exit mode<br />
for the selected area and the area actually.<br />
2 - Entry 1 Delay - for Areas A to D (A to H) (A to P)<br />
If the area is armed and an ‘Entry/Exit 1’ zone is activated,<br />
this timer will start and the entry tone will be heard. If the area<br />
is not disarmed before this timer expires, the ‘2nd Entry Delay’<br />
timer will start.<br />
3 - Entry 2 Delay - for Areas A to D (A to H) (A to P)<br />
If the area is armed and an ‘Entry/Exit 2’ zone is activated,<br />
this timer will start and the entry tone will be heard. If the area<br />
is not disarmed before this timer expires, the ‘2nd Entry Delay’<br />
timer will start.<br />
4 - 2nd Entry Dly - for Areas A to D (A to H) (A to P)<br />
When the area ‘Entry Delay 1 or 2’ timer expires, this timer will<br />
start and an Internal alarm will occur. If the area is still not<br />
disarmed before this timer expires, an Intruder alarm will then<br />
occur.<br />
5 - Bell Delay - for Areas A to D (A to H) (A to P)<br />
This timer controls the delay between an Intruder alarm<br />
occurring in the selected area and the ‘Bell/Strobe’ output<br />
activating.<br />
6 - Bell Duration - for Areas A to D (A to H) (A to P)<br />
This timer controls the duration of the ‘Bell’ output after an<br />
Intruder alarm has occurred in the selected area and any<br />
programmed ‘Bell Delay’ has expired.<br />
7 - Coms Delay. for Areas A to D (A to H) (A to P)<br />
This timer controls the delay between an Intruder alarm<br />
occurring in the selected area and the communicator reporting to<br />
the Alarm Receiving Centre.<br />
8 - Part Bell Dly. for Areas A to D (A to H) (A to P)<br />
When the selected area is ‘Part Armed’ this timer controls the<br />
delay between an Intruder alarm occurring in the selected<br />
area and the ‘Bell/Strobe’ output activating, the internal<br />
sounders will also sound during this time as a warning.<br />
INS176 37