<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> Programming the Control Panel<br />

5.2 Area Programming<br />

Timers<br />

<br />

<br />

Yes<br />

<br />

<br />

Yes<br />

<br />

<br />

<br />

<br />

Reset<br />

Yes<br />

<br />

<br />

???<br />

<br />

<br />

Yes<br />

Use the SCROLL key to<br />

select an area<br />

Press YES to move to<br />

the required timer group<br />

or press RESET to move<br />

backwards e.g. YES<br />

Enter a new timer value<br />

e.g. 025 = 25 Seconds<br />

These groups of ‘Area’ timers control timing and delay<br />

functions for areas 1 – 4 (<strong>Premier</strong> <strong>48</strong>), 1 - 8 (<strong>Premier</strong> <strong>88</strong>) and 1<br />

- 16 (<strong>Premier</strong> <strong>168</strong> and <strong>640</strong>). Each timer can be programmed<br />

for any value between 000 and 999.<br />

1 - Exit Delay- for Areas A to D (A to H) (A to P)<br />

When the area exit mode is programmed as ‘Timed’ this timer<br />

controls the delay between the user initiating the exit mode<br />

for the selected area and the area actually.<br />

2 - Entry 1 Delay - for Areas A to D (A to H) (A to P)<br />

If the area is armed and an ‘Entry/Exit 1’ zone is activated,<br />

this timer will start and the entry tone will be heard. If the area<br />

is not disarmed before this timer expires, the ‘2nd Entry Delay’<br />

timer will start.<br />

3 - Entry 2 Delay - for Areas A to D (A to H) (A to P)<br />

If the area is armed and an ‘Entry/Exit 2’ zone is activated,<br />

this timer will start and the entry tone will be heard. If the area<br />

is not disarmed before this timer expires, the ‘2nd Entry Delay’<br />

timer will start.<br />

4 - 2nd Entry Dly - for Areas A to D (A to H) (A to P)<br />

When the area ‘Entry Delay 1 or 2’ timer expires, this timer will<br />

start and an Internal alarm will occur. If the area is still not<br />

disarmed before this timer expires, an Intruder alarm will then<br />

occur.<br />

5 - Bell Delay - for Areas A to D (A to H) (A to P)<br />

This timer controls the delay between an Intruder alarm<br />

occurring in the selected area and the ‘Bell/Strobe’ output<br />

activating.<br />

6 - Bell Duration - for Areas A to D (A to H) (A to P)<br />

This timer controls the duration of the ‘Bell’ output after an<br />

Intruder alarm has occurred in the selected area and any<br />

programmed ‘Bell Delay’ has expired.<br />

7 - Coms Delay. for Areas A to D (A to H) (A to P)<br />

This timer controls the delay between an Intruder alarm<br />

occurring in the selected area and the communicator reporting to<br />

the Alarm Receiving Centre.<br />

8 - Part Bell Dly. for Areas A to D (A to H) (A to P)<br />

When the selected area is ‘Part Armed’ this timer controls the<br />

delay between an Intruder alarm occurring in the selected<br />

area and the ‘Bell/Strobe’ output activating, the internal<br />

sounders will also sound during this time as a warning.<br />