The Programming Menu <strong>Premier</strong> <strong>48</strong>, <strong>88</strong> & <strong>168</strong> <strong>Installation</strong> <strong>Manual</strong><br />
5. Programming the Control Panel<br />
Introduction<br />
All engineers should read this section carefully so as to<br />
familiarise themselves with the programming of the control<br />
panel.<br />
To access the Programming menu, enter the factory default<br />
Engineer code .<br />
If a mistake is made whilst entering the Engineer code, simply reenter<br />
the correct code.<br />
WARNING<br />
When an Engineers code is entered to gain<br />
access to the Programming menu, by default<br />
ALL zones and tampers are disabled.<br />
On all panels prior to Version 3.0 <strong>Premier</strong> <strong>48</strong><br />
and Version 6.0 <strong>Premier</strong> <strong>88</strong>/<strong>168</strong>,<br />
the Strobe output also pulse 3 times,<br />
invoking Engineers Hold Off mode if a<br />
Texecom bell box is connected.<br />
A menu option can then be selected by pressing one of the<br />
keys shown or by using the key to search. Once<br />
selected, press YES to access that option.<br />
To leave the selected menu option and return to the main<br />
programming menu, press .<br />
To exit from the Main Programming menu but still remain<br />
‘Logged’ onto the system (zones and tampers still disabled),<br />
press and the display will show ‘Alarm Engineer<br />
Working On Site’.<br />
To log the Engineer off the system, press followed by<br />
YES and the system will revert to its normal condition.<br />
The table below shows the menu options available:<br />
Key Menu Option Page<br />
Zone Setup 33<br />
Area Programming 37<br />
Global Options 44<br />
Keypad Setup 53<br />
Expander Setup 55<br />
System Outputs 57<br />
UDL/Digi Options 64<br />
Setup Users 78<br />
Engineer Utils 84<br />
Alter Part Arms 92<br />
The Arming Menu -<br />
The User Menu -<br />
Log Off Engineer 32<br />
Exit programming mode 32<br />
<br />
<br />
Enter Engineers Code<br />
<br />
<br />
30 INS176<br />
1<br />
2 abc<br />
3 def<br />
4 ghi<br />
5 jkl<br />
6 mno<br />
7 pqrs<br />
8 tuv<br />
9 wxyz<br />
Part<br />
Menu<br />
Menu<br />
0 _<br />
Reset<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Out of Programming Menu<br />
(Engineer Still Logged On)<br />
Yes