Commissioning and Troubleshooting <strong>Premier</strong> <strong>48</strong>, <strong>88</strong> & <strong>168</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Expander<br />
Expander does not operate at all<br />
• Check that the expander is wired correctly from the<br />
control panel (see page 12 for wiring details)<br />
• Check the network fuses F3 and F5 and replace if blown<br />
System does not recognise zones<br />
• If the expander is on a long cable run, check the voltage<br />
between the + and – terminals at the expander and<br />
ensure that it measures no less than 10.0V<br />
The speaker output does not work<br />
• The expander can be configured so that Alarm, Entry,<br />
Exit, Chime tones etc. can be enabled or disabled.<br />
Check that the expander has been programmed<br />
correctly (see page 56 for details)<br />
• The speaker volume on the expander is electronically<br />
adjustable. Check the volume is set to the desired level<br />
(see page 56 for details)<br />
Zones<br />
One or more zones show an alarm<br />
• Check that the zone is wired correctly (see page 19 for<br />
wiring details)<br />
Communicator<br />
The Communicator will not dial<br />
• By default the communicator is disabled, check that the<br />
communicator is enabled (see page 68 for details)<br />
• Check that the telephone line has been correctly wired to<br />
the communicator (see page 22 for wiring details)<br />
• Check that the telephone numbers are programmed<br />
correctly (see page 67 for details)<br />
• Check that the account numbers are programmed<br />
correctly (see page 67 for details)<br />
• Check that the dial attempts are not programmed as zero<br />
(see page 67 for details)<br />
• Check that the reporting areas have been programmed<br />
correctly (see page 67 for details)<br />
• Check that the reporting options have been programmed<br />
correctly (see page 67 for details)<br />
Communicator dials but does not communicate<br />
• Check that the telephone numbers are programmed<br />
correctly (see page 67 for details)<br />
• Check that the correct protocol is programmed (see<br />
page 67 for details)<br />
Operation<br />
The system will not allow me to arm<br />
• Check that there are no outstanding problems (see page<br />
27 for details)<br />
• Check that there are no outstanding alarms that require<br />
resetting<br />
• Check that the User code has been programmed to<br />
allow arming (see page 82 for details)<br />
• Check that the User code has been assigned to the<br />
correct areas (see page 80 for details)<br />
• If a ‘Local’ User code is being used (see page 82 for<br />
details) ensure that the keypad being used is assigned<br />
to the correct area (see page 53 for details)<br />
The system will not allow me to disarm<br />
• Check that the User code has been programmed to<br />
allow disarming (see page 82 for details)<br />
• Check that the User code has been assigned to the<br />
correct area(s) (see page 80 for details)<br />
• If a ‘Local’ User code is being used (see page 82 for<br />
details) ensure that the keypad being used is assigned<br />
to the correct area (see page 53 for details)<br />
26 INS176