Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Installation</strong> <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
PC-Com<br />
The PC-Com has two connectors. The 9-way D-type connector is<br />
for connection to a serial port on a computer and the Molex<br />
connector plugs onto Com 1 on the control panel.<br />
UNI-Com<br />
The UNI-Com has two connectors. The 9-way D-type<br />
connector connects to any supported serial device, the Molex<br />
connector plugs onto Com 1 on the control panel.<br />
PRINT-Com<br />
The PRINT-Com has two connectors. The 25-way D-type<br />
connector connects to a Serial Printer and the Molex<br />
connector plugs onto Com 1 on the control panel.<br />
RPD-Com<br />
The RPD-Com has two connectors. The 25-way D-type<br />
connector connects to a Paknet Radio-Pad and the Molex<br />
connector plugs onto Com 2 on the control panel.<br />
GSM-Com<br />
The GSM-Com has two connectors. The RJ45 connector connects<br />
to a GSM Module, the Molex connector plugs onto Com 2 on the<br />
control panel.<br />
Connecting a Computer<br />
The <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> and <strong>640</strong> all support local uploading<br />
and downloading between the control panel and a PC<br />
running Wintex UDL software. Uploading and Downloading<br />
can be used to program and interrogate the control panel.<br />
In order for the computer to work correctly, ensure that it is<br />
set to the following:<br />
• UDL Password (see page 70 for details)<br />
24 INS176<br />
<br />
Com 2 Com 1<br />
F2<br />
Network 2<br />
1Amp<br />
F3 F5 F1<br />
Eng ineer R emote<br />
Jp9<br />
Network 1<br />
1Amp<br />
Load<br />
Defaults<br />
JP6<br />
JP2<br />
In order to upload and download to the control panel<br />
locally, a PC-Com lead is required.<br />
Aux 12v 1Amp<br />
JP5<br />
JP7<br />
Heartbeat<br />
Expansio n<br />
Box<br />
Tamp<br />
F4<br />
PC-Com<br />
Connecting a Printer<br />
The <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> and <strong>640</strong> all support printer facilities.<br />
The printer is connected to the Com 1 connector located on<br />
the control panel and can be used to print the control panel<br />
event log.<br />
In order for the printer to work correctly, ensure that it is set to<br />
the following:<br />
• Baud Rate = <strong>48</strong>00<br />
• Parity = None<br />
• Start Bits = 1<br />
• Stop Bits = 2<br />
• Data Bits = 8<br />
• DTR = Normal<br />
• Columns = 40 or 80 (see page 47)<br />
<br />
Connect to<br />
COM1<br />
In order to connect a printer to the control panel, a<br />
PRINT-Com lead is required.<br />
PRINT-Com<br />
RS232 Data<br />
DATAC or RS232 printer