<strong>Installation</strong> <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
Plug-on Communicators<br />
The Com300 is a multi format 8-channel digital<br />
communicator/300-baud modem for use with a standard<br />
analogue telephone line.<br />
The Com2400 is a multi format 8-channel digital<br />
communicator/2400-baud modem for use with a standard<br />
analogue telephone line in addition, this modem can also send<br />
Short Message Service (SMS) text messages to a mobile<br />
phone.<br />
The ComISDN is a multi format 8-channel digital<br />
communicator/modem for use with an ISDN telephone line.<br />
These Communicators can be used to report system events to<br />
an Alarm Receiving Centre using Fast Format, Contact ID or<br />
SIA Level II or to upload/download control panel information<br />
using the Wintex UDL software and a PC.<br />
Plugging on the Communicator<br />
Ensure that the board is the correct way up (see below).<br />
Locate the plug into the communicator socket on the control<br />
panel and line up the mounting holes with the pillars in the<br />
base. Once all the holes line up, press down gently until the<br />
pillars snap into the holes.<br />
Box<br />
Tam p<br />
Standard Telephone Line Connections<br />
A standard telephone line must be connected to the Com300<br />
or Com2400 communicator as shown below:<br />
Master<br />
Socket<br />
T = 5 or A - White/Blue ring<br />
R = 2 or B - Blue/White ring<br />
Com300 T<br />
This terminal must be connected to<br />
the incoming AC Mains earth supply<br />
or R<br />
Com2400 T1 To other telephone<br />
R1<br />
extension sockets<br />
22 INS176<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Telephone cable<br />
Type 1/0.5mm CW1308<br />
ISDN Telephone Line Connections<br />
An ISDN telephone line must be connected to the ComISDN<br />
communicator as shown below:<br />
<br />
ISDN<br />
Terminal<br />
ComISDN<br />
RJ45<br />
Lead<br />