Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> <strong>Installation</strong><br />
Panel Outputs 1 - 5<br />
The control panel has five programmable outputs, which can<br />
be used to drive auxiliary devices such as LED’s, sounders or<br />
relays etc. (see page 57 for details). The table below shows<br />
the electrical characteristics for each output:<br />
No Max Current Type<br />
1 1A Switched -ve<br />
2 1A Switched -ve<br />
3 * 1A Switched +ve<br />
4 * 1A Switched +ve<br />
5 * 3A Relay<br />
* <strong>Premier</strong> <strong>88</strong>, <strong>168</strong> and <strong>640</strong> only<br />
Wiring Outputs<br />
The diagram below shows some typical wiring examples:<br />
<br />
For details on testing outputs, see page 86<br />
Digicom Outputs 1 - 8<br />
The control panel has eight programmable outputs, which<br />
can be used for connecting to a stand-alone communicator<br />
(see page 58 for details). The table below shows the electrical<br />
characteristics for each output:<br />
Terminal Max Current Operation<br />
1 100mA Switched 0V<br />
2 100mA Switched 0V<br />
3 100mA Switched 0V<br />
4 100mA Switched 0V<br />
5 100mA Switched 0V<br />
6 100mA Switched 0V<br />
7 100mA Switched 0V<br />
8 100mA Switched 0V<br />
L/M N/A 12V applied = Line Fault<br />
R/R N/A 0V applied to reset<br />
DC+ N/A +12V Power (unfused)<br />
DC- N/A 0V Power<br />
Wiring a Stand Alone Communicator<br />
The diagram below shows a typical wiring example:<br />
Stand Alone<br />
Communicator<br />
12V<br />
Power<br />
0V<br />
1<br />
Control<br />
Panel<br />
INS176 21<br />
<br />
Line Fault<br />
Channel Inputs<br />
Programmed<br />
as Positive<br />
Removed<br />
C<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
L / M<br />
R / R<br />
DC +<br />
DC -<br />
1<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Digicom<br />
Outputs<br />
For details on testing the digicom outputs, see page 86