Panel Outputs 1 - 5<br />

The control panel has five programmable outputs, which can<br />

be used to drive auxiliary devices such as LED’s, sounders or<br />

relays etc. (see page 57 for details). The table below shows<br />

the electrical characteristics for each output:<br />

No Max Current Type<br />

1 1A Switched -ve<br />

2 1A Switched -ve<br />

3 * 1A Switched +ve<br />

4 * 1A Switched +ve<br />

5 * 3A Relay<br />

* <strong>Premier</strong> <strong>88</strong>, <strong>168</strong> and <strong>640</strong> only<br />

Wiring Outputs<br />

The diagram below shows some typical wiring examples:<br />

<br />

For details on testing outputs, see page 86<br />

Digicom Outputs 1 - 8<br />

The control panel has eight programmable outputs, which<br />

can be used for connecting to a stand-alone communicator<br />

(see page 58 for details). The table below shows the electrical<br />

characteristics for each output:<br />

Terminal Max Current Operation<br />

1 100mA Switched 0V<br />

2 100mA Switched 0V<br />

3 100mA Switched 0V<br />

4 100mA Switched 0V<br />

5 100mA Switched 0V<br />

6 100mA Switched 0V<br />

7 100mA Switched 0V<br />

8 100mA Switched 0V<br />

L/M N/A 12V applied = Line Fault<br />

R/R N/A 0V applied to reset<br />

DC+ N/A +12V Power (unfused)<br />

DC- N/A 0V Power<br />

Wiring a Stand Alone Communicator<br />

The diagram below shows a typical wiring example:<br />

Stand Alone<br />

Communicator<br />

12V<br />

Power<br />

0V<br />

1<br />

Control<br />

Panel<br />

INS176 21<br />

<br />

Line Fault<br />

Channel Inputs<br />

Programmed<br />

as Positive<br />

Removed<br />

C<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

L / M<br />

R / R<br />

DC +<br />

DC -<br />

1<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Digicom<br />

Outputs<br />

For details on testing the digicom outputs, see page 86